Package / Case
56-VSOP
Display Type
LCD
Configuration
40 Segment
Interface
I²C
Current - Supply
120µA
Voltage - Supply
2 V ~ 6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Number Of Digits
20
Number Of Segments
160
Maximum Clock Frequency
315 KHz
Operating Supply Voltage
2 V to 6 V
Maximum Power Dissipation
400 mW
Maximum Operating Temperature
+ 85 C
Attached Touch Screen
No
Maximum Supply Current
120 uA
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Digits Or Characters
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
935278818112
PCF8576CTD
PCF8576CTD
Philips Semiconductors
6.16
The display blinking capabilities of the PCF8576 are very
versatile. The whole display can be blinked at frequencies
selected by the BLINK command. The blinking frequencies
are integer multiples of the clock frequency; the ratios
between the clock and blinking frequencies depend on the
mode in which the device is operating, as shown in
Table 3.
An additional feature is for an arbitrary selection of LCD
segments to be blinked. This applies to the static and
1 : 2 LCD drive modes and can be implemented without
any communication overheads. By means of the output
Table 3 Blinking frequencies
2001 Oct 02
Universal LCD driver for low multiplex rates
BLINKING MODE
Blinker
0.5 Hz
2 Hz
1 Hz
Off
NORMAL OPERATING
MODE RATIO
------------------- -
184320
------------------- -
368640
--------------- -
92160
f
f
f
clk
clk
clk
17
bank selector, the displayed RAM banks are exchanged
with alternate RAM banks at the blinking frequency. This
mode can also be specified by the BLINK command.
In the 1 : 3 and 1 : 4 multiplex modes, where no alternate
RAM bank is available, groups of LCD segments can be
blinked by selectively changing the display RAM data at
fixed time intervals.
If the entire display is to be blinked at a frequency other
than the nominal blinking frequency, this can be effectively
performed by resetting and setting the display enable bit E
at the required rate using the MODE SET command.
POWER-SAVING MODE
RATIO
--------------- -
15360
--------------- -
30720
--------------- -
61440
f
f
f
clk
clk
clk
NOMINAL BLINKING
FREQUENCY
Product specification
blinking off
0.5 Hz
2 Hz
1 Hz