MCP3909-I/SS Microchip Technology, MCP3909-I/SS Datasheet - Page 95

IC POWER METERING-1 PHASE 24SSOP

MCP3909-I/SS

Manufacturer Part Number
MCP3909-I/SS
Description
IC POWER METERING-1 PHASE 24SSOP
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909-I/SS

Package / Case
24-SSOP (0.200", 5.30mm Width)
Input Impedance
390 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.85V
Current - Supply
2.3mA
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Meter Type
Single Phase
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Supply Voltage Range
4.5V To 5.5V
Digital Ic Case Style
SSOP
No. Of Pins
24
Interface Type
Serial, SPI
Supply Voltage Max
5.5V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MCP3909EV-MCU16 - EVALUATION BOARD FOR MCP3909MCP3909RD-3PH1 - REF DESIGN MCP3909 3PH ENGY MTR
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP3909-I/SS
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
C.13 COMPENSATION FOR RATIO ERROR AND PHASE LAG
TABLE C-1:
© 2009 Microchip Technology Inc.
0.1
0.2
0.5
1
3
5
1
50
3
5
Rated Current (%)
Rated Current (%)
0.75
0.4
1.5
Ratio Error± (%)
5
3
ACCURACY CLASS AND ERROR LIMIT FOR THE CURRENT TRANSFORMER
The error of the current transformer (CT) is a complex, which can usually be expressed
by two orthogonal parts, current error (f) and phase lag (δ).
EQUATION C-63:
The current error, also known as ratio error, can be written in percentage as:
EQUATION C-64:
Phase lag, also known as angle error, is the phase difference between primary and
secondary current vector, in 'minute'.
Different current transformers have different errors. Current transformers are classified
into different accuracy classes depending on their error magnitudes. The accuracy
class of a transformer is nominated by the percentage of the maximal ratio error
allowed for a given rated current.
Accuracy classes and corresponding error limits for a current transformer are listed in
Table C-1.
0.35
0.75
0.2
1.5
20
100
120
0.1
0.2
0.5
1.0
3
5
Where:
120
0.1
0.2
0.5
1.0
K
I
I
n
1
2
1
=
=
=
Phase difference of class 3 and class 5 are not specified.
Rated Current (%)
180
15
30
90
5
the rated current ratio
the primary current
the secondary current that passes I
under the test condition
± (%)
f
20
15
45
90
8
Power Calculation Theory
=
ε
100
=
100
10
30
60
f
(
------------------------ -
5
k
+
n
Phase difference
I
j
2
I
δ ⋅
1
120
Phase lag
10
30
60
I
5
1
)
1
Rated Current (%)
0.45
0.9
2.7
5.4
5
± (Grad)
1
0.24
0.45
1.35
2.7
20
DS51723A-page 95
0.15
100
0.3
0.9
1.8
0.15
120
0.9
0.3
1.8

Related parts for MCP3909-I/SS