MCP3909-I/SS Microchip Technology, MCP3909-I/SS Datasheet - Page 97

IC POWER METERING-1 PHASE 24SSOP

MCP3909-I/SS

Manufacturer Part Number
MCP3909-I/SS
Description
IC POWER METERING-1 PHASE 24SSOP
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3909-I/SS

Package / Case
24-SSOP (0.200", 5.30mm Width)
Input Impedance
390 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.85V
Current - Supply
2.3mA
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Meter Type
Single Phase
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Supply Voltage Range
4.5V To 5.5V
Digital Ic Case Style
SSOP
No. Of Pins
24
Interface Type
Serial, SPI
Supply Voltage Max
5.5V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MCP3909EV-MCU16 - EVALUATION BOARD FOR MCP3909MCP3909RD-3PH1 - REF DESIGN MCP3909 3PH ENGY MTR
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP3909-I/SS
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
C.15 RATIO ERROR COMPENSATION
© 2009 Microchip Technology Inc.
As non-linearity and inconsistency exist in the sampling circuit (including CT and
back-end shunt resistors) and the ADC circuit, it is necessary to compensate for ratio
error to the system. Figure C-9 is the transfer link of the voltage and current channels.
The compensation for ratio error is quite simple. It compares the measured value
against the actual input value under certain input conditions and obtains a correction
coefficient.
EQUATION C-65:
FIGURE C-9:
Since current has a large dynamic range, for a meter which requires high accuracy
(0.2s and 0.5s), the multi-point calibration method is needed to meet input requirement
for full range. The MCP3909 device's current channel includes an adjustable gain
amplifier. The ratio error must be recalibrated for different amplification, but only needs
to be calibrated once under the same amplification conditions.
Voltage
Current
Correction coefficient
Input
Input
Error Caused By Sampling Circuit And ADC.
Sampling resistor
Voltage primary
R0
=
Coefficient before correction
Power Calculation Theory
2000:1
CT
1:1
CT
Voltage secondary
Current secondary
Sampling resistor
Sampling resistor
×
Calibration Value
------------------------------------------ -
Measured Value
ADC
ADC
DS51723A-page 97