LM63CIMA/NOPB National Semiconductor, LM63CIMA/NOPB Datasheet - Page 12

IC TEMP SENSR REMOTE DIODE 8SOIC

LM63CIMA/NOPB

Manufacturer Part Number
LM63CIMA/NOPB
Description
IC TEMP SENSR REMOTE DIODE 8SOIC
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheet

Specifications of LM63CIMA/NOPB

Function
Fan Control, Temp Monitor
Topology
ADC (Sigma Delta), Comparator, Fan Speed Control, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 85°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Ic Output Type
Digital
Sensing Accuracy Range
± 1°C
Supply Current
1.3mA
Supply Voltage Range
3V To 3.6V
Resolution (bits)
11bit
Sensor Case Style
SOIC
No. Of Pins
8
Termination Type
SMD
Rohs Compliant
Yes
Filter Terminals
SMD
Accuracy %
1°C
For Use With
LM63EVAL - BOARD EVALUATION LM63
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*LM63CIMA
LM63CIMA
www.national.com
FIGURE 9. Fault Queue Temperature Response Diagram
1.11 ONE-SHOT REGISTER
The One-Shot Register is used to initiate a single conversion
and comparison cycle when the device is in standby mode,
after which the data returns to standby. This is not a data reg-
20057013
12
ister. A write operation causes the one-shot conversion. The
data written to this address is irrelevant and is not stored. A
zero will always be read from this register.
1.12 SERIAL INTERFACE RESET
In the event that the SMBus Master is reset while the LM63
is transmitting on the SMBDAT line, the LM63 must be re-
turned to a known state in the communication protocol. This
may be done in one of two ways:
1.
2.
When SMBDAT is Low, the LM63 SMBus state machine
resets to the SMBus idle state if either SMBData or
SMBCLK are held Low for more than 35 ms (t
All devices are to timeout when either the SMBCLK or
SMBDAT lines are held Low for 25 ms – 35 ms.
Therefore, to insure a timeout of all devices on the bus,
either the SMBCLK or the SMBData line must be held
Low for at least 35 ms.
With both SMBDAT and SMBCLK High, the master can
initiate an SMBus start condition with a High to Low
transition on the SMBDAT line. The LM63 will respond
properly to an SMBus start condition at any point during
the communication. After the start the LM63 will expect
an SMBus Address address byte.
TIMEOUT
).