LM63CIMA/NOPB National Semiconductor, LM63CIMA/NOPB Datasheet - Page 15

IC TEMP SENSR REMOTE DIODE 8SOIC

LM63CIMA/NOPB

Manufacturer Part Number
LM63CIMA/NOPB
Description
IC TEMP SENSR REMOTE DIODE 8SOIC
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheet

Specifications of LM63CIMA/NOPB

Function
Fan Control, Temp Monitor
Topology
ADC (Sigma Delta), Comparator, Fan Speed Control, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 85°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Ic Output Type
Digital
Sensing Accuracy Range
± 1°C
Supply Current
1.3mA
Supply Voltage Range
3V To 3.6V
Resolution (bits)
11bit
Sensor Case Style
SOIC
No. Of Pins
8
Termination Type
SMD
Rohs Compliant
Yes
Filter Terminals
SMD
Accuracy %
1°C
For Use With
LM63EVAL - BOARD EVALUATION LM63
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*LM63CIMA
LM63CIMA
ALERT STATUS AND MASK REGISTERS
ID AND TEST REGISTERS
[RESERVED] REGISTERS—NOT USED
Register
C0–FD
1A–1F
60–BE
22–2F
30–3F
40–45
2.3 LM63 INITIAL REGISTER SEQUENCE AND REGISTER DESCRIPTIONS IN FUNCTIONAL ORDER
The following is a Register Map grouped in functional and sequence order. Some address locations have been left blank to maintain
compatibility with LM86. Addresses in parenthesis are mirrors of named address for backwards compatibility with some older
software. Reading or writing either address will access the same 8-bit register.
2.3.1 LM63 Required Initial Fan Control Register Sequence
Important! The BIOS must follow the sequence below to configure the following Fan Registers for the LM63 before using any of
the Fan or Tachometer or PWM registers:
All other registers can be written at any time after the above sequence.
[HEX]
Step
0C
02
16
FF
06
15
17
18
20
4E
1
2
3
4
5
[4A] Write bits 0 and 1; 3 and 4. This includes tach settings if used, PWM internal clock select (1.4 kHz or 360 kHz) and
PWM Output Polarity.
[4B] Write bits 0 through 5 to program the spin-up settings.
[4D] Write bits 0 through 4 to set the frequency settings. This works with the PWM internal clock select.
Choose, then write, only one of the following:
A. [4F–5F] the Lookup Table, or
B. [4C] the PWM value bits 0 through 5.
If Step 4A, Lookup Table, was chosen and written then write [4A] bit 5 = 0.
Stepping/Die Rev. ID
Register Name
ALERT Status
ALERT Mask
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
[Register]
HEX
15
and Setup Instructions
Read/Write
Read Only
Read Only
R/W
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
POR Default
www.national.com
[HEX]
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
A4
41

Related parts for LM63CIMA/NOPB