LM63CIMA/NOPB National Semiconductor, LM63CIMA/NOPB Datasheet - Page 22

IC TEMP SENSR REMOTE DIODE 8SOIC

LM63CIMA/NOPB

Manufacturer Part Number
LM63CIMA/NOPB
Description
IC TEMP SENSR REMOTE DIODE 8SOIC
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheet

Specifications of LM63CIMA/NOPB

Function
Fan Control, Temp Monitor
Topology
ADC (Sigma Delta), Comparator, Fan Speed Control, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 85°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Ic Output Type
Digital
Sensing Accuracy Range
± 1°C
Supply Current
1.3mA
Supply Voltage Range
3V To 3.6V
Resolution (bits)
11bit
Sensor Case Style
SOIC
No. Of Pins
8
Termination Type
SMD
Rohs Compliant
Yes
Filter Terminals
SMD
Accuracy %
1°C
For Use With
LM63EVAL - BOARD EVALUATION LM63
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*LM63CIMA
LM63CIMA
www.national.com
02
the time of the read.)
16
Address
ALERT Status And Mask Registers
HEX
HEX
0x02
Hex
16
ALERT STATUS REGISTER (8-bits) (All Alarms are latched until read, then cleared if alarm condition was removed at
ALERT MASK REGISTER (8-bits)
Read/
Write
Read
Only
R/W
Bits
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Value
POR
0
0
0
0
0
0
0
0
1
0
1
0
0
1
0
0
High Alarm Mask
Remote Diode
T_CRIT Alarm
Alarm Mask
Alarm Mask
Alarm Mask
Fault Alarm
Tach Alarm
High Alarm
High Alarm
Low Alarm
Local High
Low Alarm
Remote
Remote
Remote
Remote
Remote
Remote
T_CRIT
Name
Local
Mask
Busy
Tach
When this bit is a 0, the ADC is not converting.
When this bit is set to a 1, the ADC is performing a conversion. This bit does
not affect ALERT status.
When this bit is a 0, the internal temperature of the LM63 is at or below the Local
High Setpoint.
When this bit is a 1, the internal temperature of the LM63 is above the Local
High Setpoint, and an ALERT is triggered.
This bit is unused and always read as 0.
When this bit is a 0, the temperature of the Remote Diode is at or below the
Remote High Setpoint.
When this bit is a 1, the temperature of the Remote Diode is above the Remote
High Setpoint, and an ALERT is triggered.
When this bit is a 0, the temperature of the Remote Diode is at or above the
Remote Low Setpoint.
When this bit is a 1, the temperature of the Remote Diode is below the Remote
Low Setpoint, and an ALERT is triggered.
When this bit is a 0, the Remote Diode appears to be correctly connected.
When this bit is a 1, the Remote Diode may be disconnected or shorted. This
Alarm does not trigger an ALERT.
When this bit is a 0, the temperature of the Remote Diode is at or below the
T_CRIT Limit.
When this bit is a 1, the temperature of the Remote Diode is above the T_CRIT
Limit, and an ALERT is triggered..
When this bit is a 0, the Tachometer count is lower than or equal to the
Tachometer Limit (the RPM of the fan is greater than or equal to the minimum
desired RPM).
When this bit is a 1, the Tachometer count is higher than the Tachometer Limit
(the RPM of the fan is less than the minimum desired RPM), and an ALERT is
triggered. Note that if this bit is set, the function of the ALERT/Tach pin must be
Tach input, so an external ALERT condition will not be generated. The user may
read the status register periodically to find out if and ALERT condition has
occurred.
This bit is unused and always read as 1.
When this bit is a 0, a Local High Alarm event will generate an ALERT.
When this bit is a 1, a Local High Alarm will not generate an ALERT
This bit is unused and always read as 1.
When this bit is a 0, Remote High Alarm event will generate an ALERT.
When this bit is a 1, a Remote High Alarm event will not generate an ALERT.
When this bit is a 0, a Remote Low Alarm event will generate an ALERT.
When this bit is a 1, a Remote Low Alarm event will not generate an ALERT.
This bit is unused and always read as 1.
When this bit is a 0, a Remote T_CRIT event will generate an ALERT.
When this bit is a 1, a Remote T_CRIT event will not generate an ALERT.
When this bit is a 0, a Tach Alarm event will generate an ALERT.
When this bit is a 1, a Tach Alarm event will not generate an ALERT.
22