MAX6604AATA+T Maxim Integrated Products, MAX6604AATA+T Datasheet - Page 10

no-image

MAX6604AATA+T

Manufacturer Part Number
MAX6604AATA+T
Description
IC TEMP SENSOR DDR PREC 8-TDFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6604AATA+T

Function
Temp Monitoring System (Sensor)
Sensor Type
Internal
Sensing Temperature
-20°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-20°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-TDFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Topology
-
Similarly, the below alarm window bit (bit 13 of the tem-
perature register) is set to 0 (temperature is equal to or
above the alarm window lower boundary trip tempera-
ture) when the value in the temperature register is equal
to or greater than the value in the alarm-temperature
lower-boundary register. As the temperature decreas-
es, bit 13 is set to 1 when the value in the temperature
register is equal to or less than the value in the alarm-
temperature lower-boundary register minus 3°C.
Note that hysteresis is also applied to EVENT output
functionality. When either of the lock bits is set, the hys-
Precision Temperature Monitor for
DDR Memory Modules
Table 4. Configuration Register (Read/Write) (continued)
Table 5. Alarm-Temperature Upper-Boundary Trip Register (Read/Write)
10
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10
15:11
10:9
BIT
8
______________________________________________________________________________________
Shutdown mode
0 = Enable temperature monitoring (default)
1 = Shutdown temperature monitoring
When shutdown occurs, the thermal-sensing device and analog-to-digital converter are disabled to save power;
no EVENT output signals are generated. When either of the lock bits is set, this bit cannot be set until unlocked. However,
it can be cleared at any time.
Hysteresis enable
00 = Disable hysteresis
01 = Enable hysteresis at 1.5°C
10 = Enable hysteresis at 3°C
11 = Enable hysteresis at 6°C
0: Reserved for future use (RFU). Must be zero.
DEFINITION (DESCRIPTIONS IN BOLD TYPE ARE THE DEFAULT VALUES)
Bit 9
Bit 9
Bit 8
Bit 8
Bit 7
Bit 7
teresis bits cannot be altered. Hysteresis is applied to
both alarm window comparisons and critical tempera-
ture comparisons.
The data format for the upper-boundary trip threshold is in
two’s complement with one LSB = 0.25°C. The alarm-
temperature upper-boundary trip register has a -256.00°C
to +255.75°C range. All unused bits are set to zero.
Alarm-Temperature Upper-Boundary Trip
Bit 6
Bit 6
Bit 5
Bit 5
[Address = 02h, POR = 0000h]
Bit 4
Bit 4
Register (Read/Write)
Bit 3
Bit 3
Bit 2
Bit 2
Bit 1
Bit 1
Bit 0
Bit 0

Related parts for MAX6604AATA+T