MAX6604AATA+T Maxim Integrated Products, MAX6604AATA+T Datasheet - Page 7

no-image

MAX6604AATA+T

Manufacturer Part Number
MAX6604AATA+T
Description
IC TEMP SENSOR DDR PREC 8-TDFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6604AATA+T

Function
Temp Monitoring System (Sensor)
Sensor Type
Internal
Sensing Temperature
-20°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-20°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-TDFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Topology
-
The EVENT output indicates conditions such as the
temperature crossing a predefined boundary. It oper-
ates in one of the three modes: interrupt mode, com-
parator mode, and critical-temperature-only mode.
Figure 3 shows an example of the measured tempera-
ture vs. time, with the corresponding behavior of the
EVENT output in each of these modes. See the EVENT
Operation Modes section for descriptions of the two
modes. The EVENT modes are selected using the con-
figuration register.
Event-output polarity can be set to active high or active
low through the configuration register (bit 1). The
EVENT output can also be disabled so that EVENT is
always high impedance (bit 3). Upon device power-up,
the default condition for the EVENT output is high
impedance. Writing a 1 to bit 3 of the configuration reg-
ister enables the EVENT output.
The MAX6604 provides a comparison window with an
upper-temperature trip point and a lower-temperature
trip point, programmed through the alarm-upper-
boundary register and the alarm-lower-boundary regis-
ter, respectively. When enabled, the EVENT output
Figure 3. EVENT Behavior in Interrupt, Comparator, and Critical-Temperature-Only Modes
EVENT-Output Functionality
ALARM WINDOW
_______________________________________________________________________________________
CRITICAL
EVENT# IN INTERRUPT
EVENT# IN COMPARATOR MODE
EVENT# IN CRITICAL-TEMPERATURE-ONLY MODE
TEMP
EVENT Thresholds
S/W CLEARS EVENT
Precision Temperature Monitor for
Alarm Window Trip
triggers whenever entering or exiting (crossing above
or below) the alarm window (Figure 3).
The critical temperature setting is programmed in the
critical temperature register. When the temperature
reaches the critical temperature value in this register
(and EVENT is enabled), the EVENT output asserts and
cannot be deasserted until the temperature drops
below the critical temperature threshold.
In comparator mode, the EVENT output behaves like a
window-comparator output that asserts when the tem-
perature is outside the window. Reads/writes on the
MAX6604’s registers do not affect the EVENT output in
comparator mode. The EVENT signal remains asserted
until the temperature goes inside the alarm window or
the window thresholds are reprogrammed so that the
current temperature is within the alarm window.
In interrupt mode, EVENT asserts whenever the temper-
ature crosses an alarm window threshold. After such an
event occurs, writing a 1 to the clear event bit in the con-
figuration register deasserts the EVENT output until the
next trigger condition occurs. The trip threshold value in
DDR Memory Modules
EVENT Operation Modes
Comparator Mode
TIME
Interrupt Mode
Critical Trip
7