HCPL-J314 Avago Technologies US Inc., HCPL-J314 Datasheet - Page 5

no-image

HCPL-J314

Manufacturer Part Number
HCPL-J314
Description
OPTOCOUPLER 1CH 0.6A 8-DIP
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-J314

Package / Case
8-DIP (0.300", 7.62mm)
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
600mA
Propagation Delay High - Low @ If
300ns @ 8mA
Current - Dc Forward (if)
25mA
Input Type
DC
Output Type
Push-Pull, Totem-Pole
Mounting Type
Through Hole
Isolation Voltage
3750 Vrms
Maximum Fall Time
50 ns
Maximum Forward Diode Current
25 mA
Maximum Rise Time
50 ns
Minimum Forward Diode Voltage
1.2 V
Output Device
Integrated Photo IC
Configuration
1 Channel
Maximum Forward Diode Voltage
1.8 V
Maximum Reverse Diode Voltage
3 V
Maximum Power Dissipation
260 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-J314
Manufacturer:
AVAGO
Quantity:
2 100
Part Number:
HCPL-J314
Manufacturer:
AGILENT
Quantity:
20 000
Part Number:
HCPL-J314-000E
Manufacturer:
AVAGO
Quantity:
10 000
Part Number:
HCPL-J314-300E
Manufacturer:
AVAGO
Quantity:
10 000
Part Number:
HCPL-J314-300E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
HCPL-J314-500E
Manufacturer:
AVAGO
Quantity:
10 000
Part Number:
HCPL-J314-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V
for rated mains voltage ≤ 600 V
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V
Partial discharge < 5 pC
Highest Allowable Overvoltage (Transient Overvoltage t
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
Input Current**
Output Power**
Insulation Resistance at T
*Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, IEC/
EN/DIN EN 60747-5-2 for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of P
5
for rated mains voltage ≤ 300 V
800
700
600
500
400
300
200
100
IORM
IORM
0
0
T
x 1.875 = V
x 1.5 = V
25
S
– CASE TEMPERATURE – °C
50
75 100
HCPL-J314
PR
, Type and Sample Test, t
PR
, 100% Production Test with t
125
S
P
I
, V
S
150 175
S
(mA)
(mW)
IO
= 500 V
rms
200
rms
rms
S
and I
m
= 60 sec,
S
on ambient temperature.
m
= 1 sec,
ini
= 10 sec)
Symbol
V
V
V
V
T
I
P
R
S,INPUT
S
IORM
PR
PR
IOTM
S, OUTPUT
S
Characteristic
I - IV
I - IV
I - III
55/100/21
2
891
1670
1336
6000
175
400
1200
>10
9
Unit
V
V
V
V
°C
mA
mW
Ω
peak
peak
peak
peak