EXII-7720SC 3M, EXII-7720SC Datasheet - Page 10

CONTROLLER EX II SER CAPACITIVE

EXII-7720SC

Manufacturer Part Number
EXII-7720SC
Description
CONTROLLER EX II SER CAPACITIVE
Manufacturer
3M
Series
MicroTouch™ Controller EXr
Datasheets

Specifications of EXII-7720SC

Accessory Type
Touch Screen - Controller
Operating Supply Voltage
5 VDC to 12 VDC
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 40 C
Connector Type
RS232
Rohs Compliant
Yes
For Use With/related Products
Touch Screen Capacitive
For Use With
3M5754 - TOUCH SCREEN CAPACITIVE 12.31"3M5752 - TOUCH SCREEN CAPACITIVE 19.75"3M5750 - TOUCH SCREEN CAPACITIVE 20.65"3M5748 - TOUCH SCREEN CAPACITIVE 17.54"3M5747 - TOUCH SCREEN CAPACITIVE 6.71"3M5745 - TOUCH SCREEN CAPACITIVE 15.68"3M5744 - TOUCH SCREEN CAPACITIVE 10.83"3M5527 - TOUCH SCREEN CAPACITIVE 31.80"3M5526 - TOUCH SCREEN CAPACITIVE 20.65"3M5525 - TOUCH SCREEN CAPACITIVE 19.75"3M5524 - TOUCH SCREEN CAPACITIVE 17.54"3M5523 - TOUCH SCREEN CAPACITIVE 15.68"3M5522 - TOUCH SCREEN CAPACITIVE 12.31"3M5521 - TOUCH SCREEN CAPACITIVE 10.83"3M5520 - TOUCH SCREEN CAPACITIVE 8.75"3M5519 - TOUCH SCREEN CAPACITIVE 6.71"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
3M5540

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EXII-7720SC
Manufacturer:
3M Touch Systems
Quantity:
135
10
Handling and ESD Protection
EX Serial Controller Communication Connections
When mounting the sensor and controller, use normal precautions for handling
electrostatic sensitive devices. The EX serial controllers have internal protection to ±27
kV for ESD discharges to the sensor (not to the controller directly) that may occur during
normal operation of the sensor. Refer to the appendices for further specifications.
You will need a method of establishing the serial data communication between the
controller and your system. You can build your own or purchase the standard 3M™
MicroTouch™ RS-232 serial cable (P/N 7310101). Table 1 describes the pins for this
cable, which connects to a serial communication (COM) port on the PC.
Table 1 COM Connections for EX Serial Controllers
9-pin D
1
2
3
4
5
6
7
8
9
Sleeve
Pin
Shell
A method of establishing the serial data communication between the controller and
your system. The standard 3M™ MicroTouch™ RS-232 serial cable (P/N 7310101)
is recommended.
A method of supplying power to the controller -- either internal or external.
A touch driver with a calibration routine. You can use 3M™ MicroTouch™ MT 7
software which includes the necessary touch driver and utilities software.
2
3
5
1
4
Not used
7
7-pin Molex Wire Color Description
No
connection
No
connection
No
connection
6
7
3M Touch Systems, Inc. Proprietary Information
———
Brown
Red
———
Blue
———
Black
Green
White
Shield
———
3M™ MicroTouch™ Controller EX Serial Reference Guide
Transmit Data (TXD). Pin 2 is the controller’s
Receive Data (RXD). Pin 3 is the controller’s
Data Carrier Detect (DCD).
Connected to DTR and DSR.
output to the host.
receive from the host.
Data Terminal Ready (DTR).
Connected to DSR and DCD.
Power supply ground.
Data Set Ready (DSR).
Connected to DTR and DCD.
Request To Send (RTS).
Connected to CTS.
Clear To Send (CTS).
Connected to RTS.
DC power jack (+5 VDC).
Cable shield connected to ground
DC power jack (ground)
Chassis (earth) ground.

Related parts for EXII-7720SC