EXII-7720SC 3M, EXII-7720SC Datasheet - Page 23

CONTROLLER EX II SER CAPACITIVE

EXII-7720SC

Manufacturer Part Number
EXII-7720SC
Description
CONTROLLER EX II SER CAPACITIVE
Manufacturer
3M
Series
MicroTouch™ Controller EXr
Datasheets

Specifications of EXII-7720SC

Accessory Type
Touch Screen - Controller
Operating Supply Voltage
5 VDC to 12 VDC
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 40 C
Connector Type
RS232
Rohs Compliant
Yes
For Use With/related Products
Touch Screen Capacitive
For Use With
3M5754 - TOUCH SCREEN CAPACITIVE 12.31"3M5752 - TOUCH SCREEN CAPACITIVE 19.75"3M5750 - TOUCH SCREEN CAPACITIVE 20.65"3M5748 - TOUCH SCREEN CAPACITIVE 17.54"3M5747 - TOUCH SCREEN CAPACITIVE 6.71"3M5745 - TOUCH SCREEN CAPACITIVE 15.68"3M5744 - TOUCH SCREEN CAPACITIVE 10.83"3M5527 - TOUCH SCREEN CAPACITIVE 31.80"3M5526 - TOUCH SCREEN CAPACITIVE 20.65"3M5525 - TOUCH SCREEN CAPACITIVE 19.75"3M5524 - TOUCH SCREEN CAPACITIVE 17.54"3M5523 - TOUCH SCREEN CAPACITIVE 15.68"3M5522 - TOUCH SCREEN CAPACITIVE 12.31"3M5521 - TOUCH SCREEN CAPACITIVE 10.83"3M5520 - TOUCH SCREEN CAPACITIVE 8.75"3M5519 - TOUCH SCREEN CAPACITIVE 6.71"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
3M5540

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EXII-7720SC
Manufacturer:
3M Touch Systems
Quantity:
135
3M™ MicroTouch™ Controller EX Serial Reference Guide
Response:
Calibrate Raw
Syntax:
*The coordinates are in video terms, with the origin (0, 0) in the upper left corner of the sensor. Examples from the
controller’s perspective, however, place the origin at the lower left corner of the sensor (numbers in brackets). The
controller outputs 0 to 64K on both axes independent of display screen resolution.
The Calibrate Extended command then positions the first calibration target inward from
the lower left corner and the second calibration target inward from the upper right corner.
The following illustration shows how the calibration targets are calculated.
Calibrate Extended Procedure
To use the CX command:
1. Enter the Calibrate Extended (CX) command. The controller sends an initial
2. Touch the sensor at a lower left target, which is located 12.5% (1/8) in from the
3. Touch the sensor at an upper right target, which is located 12.5% (1/8) in from the
Touching the two valid calibration points results in a successful calibration. If either
calibration point is invalid, the calibration fails. The EX122 and EX112 controllers
restore the previous calibration values. If the Calibrate Extended failed, repeat the CX
process.
<SOH>1<CR>
Indicates that the controller received a valid touch coordinate (point) when the target was
touched. Two valid touch points indicate a successful calibration.
<SOH>0<CR>
Indicates that the touch point is out of range of the expected target area. If you receive a
negative response, you must start over again.
No Response
Indicates that you did not touch the target long enough to provide an accurate calibration
point.
<SOH>CR<CR>
acknowledgment of <SOH>0<CR>.
corner of the video image. The controller returns an acknowledgment of
<SOH>1<CR>. This is a positive response. If you receive a negative response
<SOH>0<CR>, you can cancel the calibration by issuing a Reset command and then
start over again.
corner of the video image. The controller returns an acknowledgment of
<SOH>1<CR>. This is a positive response. If you receive a negative response, you
must start over again.
3M Touch Systems, Inc. Proprietary Information
Positive response.
Negative response
23