EXII-7720SC 3M, EXII-7720SC Datasheet - Page 27

CONTROLLER EX II SER CAPACITIVE

EXII-7720SC

Manufacturer Part Number
EXII-7720SC
Description
CONTROLLER EX II SER CAPACITIVE
Manufacturer
3M
Series
MicroTouch™ Controller EXr
Datasheets

Specifications of EXII-7720SC

Accessory Type
Touch Screen - Controller
Operating Supply Voltage
5 VDC to 12 VDC
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 40 C
Connector Type
RS232
Rohs Compliant
Yes
For Use With/related Products
Touch Screen Capacitive
For Use With
3M5754 - TOUCH SCREEN CAPACITIVE 12.31"3M5752 - TOUCH SCREEN CAPACITIVE 19.75"3M5750 - TOUCH SCREEN CAPACITIVE 20.65"3M5748 - TOUCH SCREEN CAPACITIVE 17.54"3M5747 - TOUCH SCREEN CAPACITIVE 6.71"3M5745 - TOUCH SCREEN CAPACITIVE 15.68"3M5744 - TOUCH SCREEN CAPACITIVE 10.83"3M5527 - TOUCH SCREEN CAPACITIVE 31.80"3M5526 - TOUCH SCREEN CAPACITIVE 20.65"3M5525 - TOUCH SCREEN CAPACITIVE 19.75"3M5524 - TOUCH SCREEN CAPACITIVE 17.54"3M5523 - TOUCH SCREEN CAPACITIVE 15.68"3M5522 - TOUCH SCREEN CAPACITIVE 12.31"3M5521 - TOUCH SCREEN CAPACITIVE 10.83"3M5520 - TOUCH SCREEN CAPACITIVE 8.75"3M5519 - TOUCH SCREEN CAPACITIVE 6.71"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
3M5540

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EXII-7720SC
Manufacturer:
3M Touch Systems
Quantity:
135
3M™ MicroTouch™ Controller EX Serial Reference Guide
Format Tablet
Syntax:
Description:
Response:
<SOH>FT<CR>
Outputs the X/Y touch coordinate data in a 5-byte packet. The packet includes 1 status
byte and 4 bytes of binary X/Y coordinate data. The protocol also establishes the X and Y
coordinate output as 14 binary bits providing a range of 0 to 16,383.
The low order bits (X3 – X0 and Y3 – Y0) are not significant in a 1024 by 1024 sensor
because data can fluctuate with each touch, and therefore may not be completely
accurate.
To use Format Tablet, the controller and host system must be in an 8-bit data
communication mode. The Format Tablet command returns a negative response if the
controller is in 7-bit format.
<SOH>0<CR>
With the controller in Format Tablet mode, touching the sensor causes the controller to
return a response in the following format:
SXxYy
S
Xx = X (horizontal) coordinate data; second and third bytes of data.
Yy = Y (vertical) coordinate data; fourth and fifth bytes of data.
Table 10 Data Sequence
Data Sequence 7
S
X
x
Y
y
*MSB = Most Significant Bit, LSB = Least Significant Bit
Table 11 defines the status bits (Byte 1) for the Format Tablet data.
= Status byte, first byte of data. Refer to Table 10.
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
3M Touch Systems, Inc. Proprietary Information
MSB*
1
0
0
0
0
Positive response.
6
S6
X6
X13
Y6
Y13
5
S5
X5
X12
Y5
Y12
Bits
4
S4
X4
X11
Y4
Y11
3
S3
X3
X10
Y3
Y10
2
S2
X2
X9
Y2
Y9
1
S1
X1
X8
Y1
Y8
S0
LSB*
0
X0
X7
Y0
Y7
27