Datasheet

Specifications of FW300F1

Output
3.3V
Number Of Outputs
1
Power (watts)
198W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
Module
1st Output
3.3 VDC @ 60A
Size / Dimension
4.60" L x 2.40" W x 0.53" H (116.8mm x 61mm x 13.5mm)
Power (watts) - Rated
198W
Operating Temperature
-40°C ~ 100°C
Efficiency
79%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FW300F1
Manufacturer:
LUCENT
Quantity:
27
Part Number:
FW300F1
Manufacturer:
SEMIKRON
Quantity:
560
Part Number:
FW300F1
Quantity:
55
Part Number:
FW300F1-33T
Manufacturer:
EUPEC
Quantity:
560
Part Number:
FW300F1-33T198W
Manufacturer:
WE
Quantity:
4 000
Part Number:
FW300F1-T
Manufacturer:
LUCENT
Quantity:
27
Part Number:
FW300F1-T
Manufacturer:
LUCENT
Quantity:
20 000
dc-dc Converters; 36 to 75 Vdc Input, 3.3 Vdc Output; 165 W to 198 W
Feature Descriptions
Forced Load Sharing (Parallel Operation)
(continued)
When not using the parallel feature, leave the
PARALLEL pin open.
Figure 23. Wiring Configuration for Redundant
Power Good Signal
The PWR GOOD pin provides an open-drain signal
(referenced to the SENSE(–) pin) that indicates the
operating state of the module. A low impedance
(<100
cates that the module is operating. A high impedance
(>1 M ) between PWR GOOD and SENSE(–) indi-
cates that the module is off or has failed. The PWR
GOOD pin can be pulled up through a resistor to an
external voltage to facilitate sensing. This external volt-
age level must not exceed 40 V, and the current into the
PWR GOOD pin during the low-impedance state
should be limited to 1 mA maximum.
14
14
) between PWR GOOD and SENSE(–) indi-
Parallel Operation
CASE
ON/OFF
V
V
CASE
ON/OFF
V
V
I
I
I
I
(+)
(-)
(+)
(-)
PARALLEL
PARALLEL
SENSE(+)
SENSE(+)
SENSE(-)
SENSE(-)
V
V
V
V
O
O
O
O
(+)
(+)
(continued)
(-)
(-)
8-581 (C)
Thermal Considerations
Introduction
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation of the unit.
Heat-dissipating components inside the unit are ther-
mally coupled to the case. Heat is removed by conduc-
tion, convection, and radiation to the surrounding
environment. Proper cooling can be verified by mea-
suring the case temperature. Peak temperature occurs
at the position indicated in Figure 24.
Note: Top view, measurements shown in millimeters and (inches).
Figure 24. Case Temperature Measurement
The temperature at this location should not exceed
100 °C. The maximum case temperature can be limited
to a lower value for extremely high reliability. The output
power of the module should not exceed the rated power
for the module as listed in the Ordering Information table.
For additional information about these modules, refer to
the Thermal Management for FC- and FW-Series 250
W—300 W Board-Mounted Power Modules Technical
Note (TN96-009EPS).
(1.20)
30.5
Pin locations are for reference only.
V
V
ON/OFF
SYNC IN
SYNC OUT
CASE
I
I
(-)
(+)
Location
TEMPER ATURE HERE
(3.25)
82.6
MEASURE CASE
Tyco Electronics Corp..
July 2002
V
V
O
8-1303 (C).a