OKI-T/3-W40P-C Murata Power Solutions Inc, OKI-T/3-W40P-C Datasheet - Page 4

CONV DC/DC 3A 15W 24VIN SMD

OKI-T/3-W40P-C

Manufacturer Part Number
OKI-T/3-W40P-C
Description
CONV DC/DC 3A 15W 24VIN SMD
Manufacturer
Murata Power Solutions Inc
Series
Okami™ OKI-T/3-W40r
Type
Point of Load (POL) Non-Isolatedr
Datasheet

Specifications of OKI-T/3-W40P-C

Output
0.75 ~ 5.5V
Number Of Outputs
1
Power (watts)
15W
Mounting Type
Surface Mount
Voltage - Input
16 ~ 40V
Package / Case
5-SMD Module
1st Output
0.75 ~ 5.5 VDC @ 3A
Size / Dimension
0.82" L x 0.47" W x 0.34" H (20.8mm x 11.9mm x 8.5mm)
Power (watts) - Rated
15W
Operating Temperature
-40°C ~ 85°C
Efficiency
88%
Approvals
EN, IEC, UL
Dc / Dc Converter O/p Type
Variable
No. Of Outputs
1
Input Voltage
16VDC To 40VDC
Power Rating
15W
Output Voltage
5.5V
Output Current
3A
Supply Voltage
24V
Product
Non-Isolated / POL
Output Power
15 W
Input Voltage Range
16 V to 40 V
Input Voltage (nominal)
24 V
Output Voltage (channel 1)
0.7525 V to 5.5 V
Output Current (channel 1)
3 A
Package / Case Size
11.9 mm x 20.8 mm x 8.5 mm
Screening Level
Industrial
Product Height (mm)
8.5mm
Mounting Style
Surface Mount
Pin Count
5
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Performance and Functional Specifi cations
See Note 1
Input Voltage Range
Isolation
Start-Up Voltage
Undervoltage Shutdown (see Note 15)
Overvoltage Shutdown
Refl ected (Back) Ripple Current (Note 2) 20 mA pk-pk
Internal Input Filter Type
Recommended External Fuse
Reverse Polarity Protection
Input Current:
Remote On/Off Control (Note 5)
Output Power
Minimum Loading
Accuracy (50% load, untrimmed)
Voltage Output Range (Note 13)
Overvoltage Protection (Note 16)
Temperature Coeffi cient
Ripple/Noise (20 MHz bandwidth)
Line/Load Regulation
Effi ciency
Maximum Capacitive Loading (Note 14)
Current Limit Inception (Note 6)
Short Circuit Mode
Dynamic Load Response
Start-Up Time
Switching Frequency
Full Load Conditions
Inrush Transient
Shutdown Mode (Off, UV, OT)
Output in Short Circuit
Low Line (Vin=Vmin)
Negative Logic (“N” model suffi x)
Current
Positive Logic (“P” model suffi x)
Current
Cap-ESR=0.001 to 0.01 Ohms
Cap-ESR >0.01 Ohms
(98% of Vout setting, after warm up)
Short Circuit Current Output
Protection Method
Short Circuit Duration
Prebias Startup
(50-100 load step, di/dt=2.5A/ μ Sec, 5 Vout, Cout = 1&10μF ceramic)
(Vin on or On/Off to Vout regulated)
Dynamic Characteristics
Output
Input
See Ordering Guide and Note 7.
Not isolated
15 V
14 V min., 15.5V max.
None
Capacitive
1.2A fast blow
N/A. See fuse information.
See Ordering Guide
0.4 A2Sec.
5 mA
60 mA
1.03A.
ON = -0.3V to +1.2V
OFF = (Vin -2.5V) to 40V or open
1 mA max.
ON = Open pin (internally pulled up) or
= (Vin -2.5V) to 40V or open
OFF = -0.3V to +1.2V
1 mA max.
15W max.
No minimum load
±2 % of Vnominal
See Ordering Guide
None
±0.02% per °C of Vout range
See Ordering Guide and note 8
See Ordering Guide and note 10
See Ordering Guide
1,000 μF
3,000 μ F (min. cap. load 0 μF )
5.5 Amps
0.0 A
Hiccup autorecovery upon overload
removal. (Note 17)
Continuous, no damage
(output shorted to ground)
Converter will start up if the external
output voltage is less than Vnominal.
125μSec max. to within ±2% of fi nal value
8 mSec for Vout=nominal (Vin On)
6 mSec for Vout=nominal (Remote On/Off)
300 KHz
www.murata-ps.com
Adjustable Output 3-Amp DOSA-SMT DC/DC Converters
Specifi cation Notes:
(1)
(2)
(3)
(4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fi xed
(4b) Mean Time Before Failure is calculated using the MIL-HDBK-217N2 method, ground benign, +25ºC., full
Calculated MTBF
Calculated MTBF
Operating Temperature Range (Ambient)
Operating PC Board Temperature
Storage Temperature Range
Thermal Protection/Shutdown
Relative Humidity
Outline Dimensions
Weight
Safety
Restriction of Hazardous Substances
MSL Rating
Input Voltage (Continuous or transient)
On/Off Control
Input Reverse Polarity Protection
Output Current (Note 7)
Storage Temperature
Lead Temperature
Absolute maximums are stress ratings. Exposure of devices to greater than any of
any of these conditions may adversely affect long-term reliability. Proper operation
under conditions other than those listed in the Performance/Functional Specifi cations
Table is not implied nor recommended.
Specifi cations are typical at +25 °C, Vin=nominal (+24V.), Vout=nominal (+5V), full load, external caps and
natural convection unless otherwise indicated. Extended tests at full power must supply substantial forced
airfl ow.
All models are tested and specifi ed with external 1 μF paralleled with 10μF ceramic/tantalum output
capacitors and a 22 μF external input capacitor. All capacitors are low ESR types. These capacitors are
necessary to accommodate our test equipment and may not be required to achieve specifi ed performance
in your applications. However, Murata Power Solutions recommends installation of these capacitors. All
models are stable and regulate within spec under no-load conditions.
Input Back Ripple Current is tested and specifi ed over a 5 Hz to 20 MHz bandwidth. Input fi ltering is Cin=2 x
100 μF tantalum, Cbus=1000 μF electrolytic, Lbus=1 μH.
Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher
temperatures and/or lower airfl ow, the DC/DC converter will tolerate brief full current outputs if the total
RMS current over time does not exceed the Derating curve.
conditions, Tpcboard=+25 ˚C, full output load, natural air convection.
output load, natural convection.
Telecordia method (4a)
See derating curves
MIL-HDBK-217N2 method (4b)
27 May 2010
Absolute Maximum Ratings
OKI-T/3-W40 Series
Environmental
Physical
MDC_OKI-T/3-W40 Series.A02 Page 4 of 13
TBD
TBD
-40 to +85 ˚C. with derating (Note 9)
-40 to +100 ˚Celsius max., no derating (12)
-55 to +125 deg. C.
+130 ˚Celsius
See Mechanical Specifi cations
0.072 ounces (2.04 grams)
Designed to meet UL/cUL 60950-1, CSA-
C22.2 No. 60950-1, IEC/EN 60950-1
RoHS-6 (does not claim EU RoHS exemption
7b–lead in solder)
0 V.to +40 Volts max.
0 V. min. to +Vin max.
See Fuse section
Current-limited. Devices can withstand a
sustained short circuit without damage.
The outputs are not intended to accept
appreciable reverse current.
-55 to +125 ˚C.
See soldering specifi cations
to 85%/+85 ˚C., non-condensing
2
email: sales@murata-ps.com

Related parts for OKI-T/3-W40P-C