FPSS1U TDK Corporation, FPSS1U Datasheet - Page 50

RACK 3 SLOT FOR FPS1000

FPSS1U

Manufacturer Part Number
FPSS1U
Description
RACK 3 SLOT FOR FPS1000
Manufacturer
TDK Corporation
Series
FPSr
Datasheets

Specifications of FPSS1U

Accessory Type
Rack System
No. Of Slots
3
Peak Reflow Compatible (260 C)
No
External Width
19.00"
Rack U Height
1
External Depth
13.82"
For Use With
285-1239 - PWR SUP FNT END 48V 1008W 21A285-1238 - PWR SUP FNT END 32V 992W 31A285-1237 - PWR SUP FNT END 24V 960W 40A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
FPS1000 Series
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1240

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FPSS1U
Manufacturer:
TDK-LAMBDA
Quantity:
232
Part Number:
FPSS1U/P
Manufacturer:
TDK-LAMBDA
Quantity:
232
CHAPTER 19 BASIC CONNECTIONS FOR OPERATION FPS-T1U RACK
19.1 Connecting Single Load, Remote Sensing
Remote sensing is used in cases where the load regulation is important at the load terminals. Use twisted
or shielded wires to minimize noise pick-up. If shielded wires are used, the shield should be connected
to the ground at one point, either the power supply side or the load. The optimal point for the shield ground
should be determined by experimentation. Refer to the power supply specifications for the maximum
voltage drop allowed at the load wires.
*
19.2 On/Off control
Fig 19-2 and Fig 19.3 shows typical connection for individual On/Off control of each installed FPS1000 unit.
Connection for negative logic:
Closed: On
Factory default: ON/OFF Control_1
In Local sense applications, the +/- sense have to be connected to the
+/-Local Sense terminals of the FPS-T1U prior to operating the FPS1000 units plugged in.
ON/
OFF_1
A
FPS-1000 Module B
FPS-1000 Module C
FPS-1000 Module A
FPS-1000 Module B
FPS-1000 Module C
FPS-1000 Module A
FPS-T1U
FPS-T1U
ON/OFF Control_1
ON/
OFF_1
B
Open: Off
ON/
OFF_1
C
Fig 19-1: Remote sensing, three load.
+V
+S
+V
+S
+V
+S
-S
-V
-S
-V
-S
-V
Fig 19-2
J1-7
J2-8
J2-7
J1-8
J3-8
J3-7
J3(C)-12
J1(A)-3
J2(B)-12
J2(B)-3
J3(C)-3
J1(A)-12
ON
ON
ON
Sense lines
Twisted pairs
Load line. Up to 1V drop.
OFF
OFF
OFF
Load line.
Up to 1V drop.
47
+V
+V
+V
-V
-V
-V
SLCT
OFF
Connection for positive logic:
Closed: Off
LOAD
ON/
LOAD
FPS-1000 Module B
FPS-1000 Module C
LOAD
FPS-1000 Module A
FPS-T1U
ON/OFF Control_2
OFF1
ON/
A
SLCT
OFF
ON/
FPS-T1U Instruction Manual
OFF1
Open: On
ON/
B
SLCT
OFF
ON/
OFF1
ON/
C
J3(C)-4
OFF
OFF
OFF
J1(A)-3
J2(B)-4
J2(B)-3
J3(C)-3
J1(A)-4
Fig 19-3
ON
ON
ON

Related parts for FPSS1U