KSZ8893MQL-EVAL Micrel Inc, KSZ8893MQL-EVAL Datasheet - Page 55

EVAL KIT EXPERIMENTAL KSZ8893MQL

KSZ8893MQL-EVAL

Manufacturer Part Number
KSZ8893MQL-EVAL
Description
EVAL KIT EXPERIMENTAL KSZ8893MQL
Manufacturer
Micrel Inc
Datasheet

Specifications of KSZ8893MQL-EVAL

Main Purpose
Interface, Ethernet Controller (PHY and MAC)
Embedded
No
Utilized Ic / Part
KSZ8893MQL
Primary Attributes
3 Ports, 100BASE-TX/100BASE-FX/10BASE-T, Managed
Secondary Attributes
MII, RMII, SNI, Auto MDI, MDI-X Auto Polarity Correction, LinkMD
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
576-1603
Near-end (Remote) Loopback
Near-end (Remote) loopback is conducted at either PHY port 1 or PHY port 2.of the KSZ8893MQL/MBL. The
loopback path starts at the PHY port’s receive inputs (RXPx/RXMx), wraps around at the same PHY port’s
PMD/PMA, and ends at the PHY port’s transmit outputs (TXPx/TXMx).
Bit [1] of registers 26 and 42 is used to enable near-end loopback for ports 1 and 2, respectively. Alternatively,
the MII Management register 31, bit [1] can be used to enable near-end loopback.
The near-end loopback paths are illustrated in the following figure.
December 2007
RXP1 /
RXM 1
RXP2 /
RXM2
Figure 13. Near-end (Remote) Loopback Path
PMD/PMA
PMD/PMA
Switch
Port 1
MAC
MAC
PHY
PCS
PCS
Port 2
PHY
55
TXP2 /
TXM2
TXP1 /
TXM 1
M9999-121007-1.5

Related parts for KSZ8893MQL-EVAL