SI2457FS18-EVB Silicon Laboratories Inc, SI2457FS18-EVB Datasheet - Page 28

no-image

SI2457FS18-EVB

Manufacturer Part Number
SI2457FS18-EVB
Description
BOARD EVAL SI2457 + SI3018 16PIN
Manufacturer
Silicon Laboratories Inc
Series
ISOmodem®r
Datasheets

Specifications of SI2457FS18-EVB

Main Purpose
Telecom, Data Acquisition Arrangement (DAA)
Utilized Ic / Part
Si2457
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Si2457/34/15/04-Si3008
4.19. Extended AT Commands
The extended AT commands are supported by the Si2457/34/15/04 and are described in Tables 12 through 14.
28
&$
&D0
&D1
&D2
&D3
&F
&Gn
&G3
&G4
&G5
&G6
&G7
&G8
&G9
&G10
&G11
&G12
&G13
&G14
&G15
&G16
&G17
&Hn
&H0
&H1
&H2
&H3
Command
Display AT& current settings.
ESC is not used
ESC escapes to command mode from data mode if also enabled by HES U70, bit 15.
ESC assertion during a modem connection causes the modem to go on-hook and return to com-
mand mode.
ESC assertion causes ATZ command (reset and return OK result code).
Restore factory default settings.
Line connection rate limit—This command sets an upper limit on the line speed that the Si2457/34/
15/04 can connect. Note that the &Hn commands may limit the line speed as well (&Gn not used for
&H0 or &H1). Not all modulations support rates given by &G. Any improper setting will be ignored.
1200 bps max
2400 bps max (default for Si2404)
4.8 kbps max
7.2 kbps max
9.6 kbps max
12 kbps max
14.4 kbps max (default for Si2415)
16.8 kbps max
19.2 kbps max
21.6 kbps max
24 kbps max
26.4 kbps max
28.8 kbps max
31.2 kbps max
33.6 kbps max (default for Si2457 and Si2434)
Switched network handshake mode—&Hn commands must be on a separate command line from
ATD, ATA, or ATO commands.
V.90 with automatic fallback (56 kbps to 300 bps) (default for Si2457)
V.90 only (56 kbps to 28 kbps)
V.34 with automatic fallback (33.6 kbps to 300 bps) (default for Si2434)
V.34 only (33.6 kbps to 2400 bps)
Table 12. Extended AT& Command Set (Command Defaults in Bold)