SI2457FS18-EVB Silicon Laboratories Inc, SI2457FS18-EVB Datasheet - Page 40

no-image

SI2457FS18-EVB

Manufacturer Part Number
SI2457FS18-EVB
Description
BOARD EVAL SI2457 + SI3018 16PIN
Manufacturer
Silicon Laboratories Inc
Series
ISOmodem®r
Datasheets

Specifications of SI2457FS18-EVB

Main Purpose
Telecom, Data Acquisition Arrangement (DAA)
Utilized Ic / Part
Si2457
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Si2457/34/15/04-Si3008
40
S-Register
(Decimal)
42
43
44
50
51
Blacklisting—The Si2457/34/15/04 will not dial the
same number more than two times in three minutes.
An attempt to dial a third time within three minutes will
result in a “BLACKLISTED” result code. If the blacklist
memory is full, any dial to a new number will result in a
“BLACKLIST FULL” result code. Numbers are added
to the blacklist only if the modem connection fails. The
%B command will list the numbers on the blacklists.
0 = disabled
1 = enabled
Dial Attempts to Blacklist.
When blacklisting is enabled with S42, this value con-
trols the number of dial attempts that will result in a
number being blacklisted.
Blacklist Timer.
Period during which blacklisting is active.
Minimum on-hook time—Modem will remain on-hook
for S50 seconds. Any attempt to go off-hook will be
delayed until this timer expires.
Number to start checking for an outside line on a PBX.
See &X command for details.
Table 16. S-Register Description (Continued)
Function
Preliminary Rev. 0.7
Definition
0 (disabled)
(Decimal)
Default
180
4
3
1
Range
0–255
0–255
0–1
0–4
0–9
seconds
seconds
Units

Related parts for SI2457FS18-EVB