ADC14DS105KARB/NOPB National Semiconductor, ADC14DS105KARB/NOPB Datasheet - Page 4

no-image

ADC14DS105KARB/NOPB

Manufacturer Part Number
ADC14DS105KARB/NOPB
Description
BOARD EVAL FOR ADC14DS105KARB
Manufacturer
National Semiconductor
Series
PowerWise®r

Specifications of ADC14DS105KARB/NOPB

Design Resources
ADC14DS105KARB Ref Design
Number Of Adc's
2
Number Of Bits
14
Sampling Rate (per Second)
105M
Data Interface
Serial
Inputs Per Adc
1 Differential
Power (typ) @ Conditions
1W @ 105MSPS
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 85°C
Utilized Ic / Part
ADC14DS105
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ADC14DS105KARB
WaveVision software.
WaveVision software (version 4.3.26) is included in this
evaluation kit on a CD-ROM.
Signal Path Digital Interface hardware is available
through the National Semiconductor website (part
number: WAVEVSN 5.1).
3.0 Evaluation Kit Contents and Board
Assembly
The ADC14DS105KARB evaluation kit includes the
following items:
The ADC14DS105KARB is factory configured for
evaluation of input signals up to 35 MHz. Each board
is populated with an analog input network which has a
lowpass filter with a cutoff frequency of approximately
35 MHz.
The LMK02000, which provides the sample clock for
the ADC, must be programmed to correctly configure it
for the proper operating frequency.
microcontroller board (ADC14PIC REV. A) is used to
program the registers of the LMK02000 precision clock
conditioner chip.
4.0 Quick Start
4.1 WaveVision Software and Hardware Installation
1. Begin by installing the latest version of the
2. Connect the WaveVision 5.1 Digital Interface
3. If this is the first time connecting a WaveVision 5.1
4. Once the WaveVision software and hardware have
For more information on installing the WaveVision data
acquisition hardware or software, please refer to the
Quick Start Guide in the WaveVision User’s Guide
N
The WaveVision software must be installed before
connecting the WaveVision hardware.
WaveVision software (version 4.3.26) which is on
the CD-ROM included in this evaluation kit. Do not
start the WaveVision software application at this
point.
Board to your PC through the supplied USB cable
and apply power to the WaveVision 5.1 board
through the +12V AC-DC power adapter included
in the WaveVision 5.1 kit. The connection diagram
is shown in Figure 3.
board to your PC, follow the on-screen instructions
for installing the drivers for the hardware.
been installed, the WaveVision software application
can be opened.
ADC14DS105KARB reference design board
PIC microcontroller board (ADC14PIC REV. A)
CD-ROM with latest WaveVision software
(4.3.26)
The latest version of the
The WaveVision 5.1
ADC14DS105KARB Reference Design Board User’s Guide
The PIC-
- 4 -
which can be found on the National Semiconductor
website
(http://www.national.com/appinfo/adc/evalboards_datac
apture.html).
Please note that the ADC14DS105KARB is only
compatible with National Semiconductor’s WaveVision
5.1 Digital Interface board.
4.2 Serial Programming Interface (SPI)
The
ADC14DS105 can be selected either through the SPI
or by direct pin control through the jumpers on the
evaluation board. The ADC14DS105KARB evaluation
board is delivered with the ADC14DS105 configured for
SPI operation.
The serial programming interface enable (SPI_EN) pin
jumper on the ADC14DS105KARB selects the state of
the SPI_EN pin. When the jumper is in place, the pin
state is asserted HIGH, the SPI is active and the direct
control pins have no effect. When the jumper is
removed, the SPI_EN state is LOW, the SPI is
deactivated and the ADC modes are pin-controlled
through the DLC, WAM, TEST jumpers. The SPI
interface is routed through the 60-pin HMZd connector
and is controlled through the WaveVision hardware and
software when the WaveVision 5.1 data capture
hardware is connected and active.
When the ADC14DS105KARB board is connected to
the WaveVision 5.1 board, the SPI software control
panel shown in Figure 3 will automatically appear. This
window should be used to set the modes of the
ADC14DS105 when the SPI is enabled. Please ensure
that the fields in the window correspond to Figure 3.
Only the field labeled “Channel” needs to be
changed to select between capture from Channel A
or Channel B.
control panel should remain unchanged. It is not
necessary to click on the “Relock DCMs” button.
channel
and
The other fields in the software
data
format
www.national.com
modes
Rev 0.2