STEVAL-ISA037V1 STMicroelectronics, STEVAL-ISA037V1 Datasheet - Page 12

BOARD EVAL BASED ON L6728

STEVAL-ISA037V1

Manufacturer Part Number
STEVAL-ISA037V1
Description
BOARD EVAL BASED ON L6728
Manufacturer
STMicroelectronics
Type
DC/DC Switching Converters, Regulators & Controllersr
Datasheets

Specifications of STEVAL-ISA037V1

Design Resources
STEVAL-ISA037V1 Gerber Files STEVAL-ISA037V1 Schematic STEVAL-ISA037V1 Bill of Material
Main Purpose
DC/DC, Step Down
Outputs And Type
1, Non-Isolated
Voltage - Output
1.25V
Current - Output
20A
Voltage - Input
5 ~ 12V
Regulator Topology
Buck
Frequency - Switching
300kHz
Board Type
Fully Populated
Utilized Ic / Part
L6728
Input Voltage
5 V to 12 V
Output Voltage
1.25 V
Product
Power Management Modules
Silicon Manufacturer
ST Micro
Silicon Core Number
L6728
Kit Application Type
Power Management - Voltage Regulator
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power - Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
L6728
Other names
497-6418
STEVAL-ISA037V1
Over current protection
8
12/31
Over current protection
The over current function protects the converter from a shorted output or overload, by
sensing the output current information across the low side MOSFET drain-source on-
resistance, R
avoiding the use of expensive and space-consuming sense resistors.
The low side R
node when LS MOSFET is turned on with the programmed OCP thresholds voltages,
internally held. If the monitored voltage is bigger than these thresholds, an over current
event is detected.
For maximum safety and load protection, L6728 implements a dual level over current
protection system:
When over current protection is triggered, the device turns off both LS and HS MOSFETs in
a latched condition.
To recover from over current protection triggered condition, VCC power supply must be
cycled.
1
PHASE exceeds this threshold, a 1
events are detected in four consecutive switching cycles, over current protection will be
triggered.
2
threshold multiplied by a factor 1.5. If the monitored voltage on PHASE exceeds this
threshold, over current protection will be triggered immediately.
st
nd
level threshold: it is the user externally set threshold. If the monitored voltage on
level threshold: it is an internal threshold whose value is equal to 1
DS(on)
DS(on)
. This method reduces cost and enhances converter efficiency by
current sense is implemented by comparing the voltage at the PHASE
st
level over current is detected. If four 1
st
level
st
level OC
L6728