STEVAL-MKI031V1 STMicroelectronics, STEVAL-MKI031V1 Datasheet - Page 30

PLATFORM MUSA

STEVAL-MKI031V1

Manufacturer Part Number
STEVAL-MKI031V1
Description
PLATFORM MUSA
Manufacturer
STMicroelectronics

Specifications of STEVAL-MKI031V1

Sensor Type
*
Sensing Range
*
Interface
*
Sensitivity
*
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
*
Voltage - Supply
*
Sensing Axis
Double Axis
Output Type
Digital
Interface Type
USB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
LPR5xxxAL, LPY5xxxAL, LY5xxxAL
Other names
497-10672
Register description
7.7
7.8
7.9
30/38
HP_FILTER_RESET (25h)
Dummy register. Reading at this address zeroes instantaneously the content of the internal
high pass-filter. If the high pass filter is enabled all three axes are instantaneously set to 0g.
This allows to overcome the settling time of the high pass filter.
REFERENCE (26h)
Table 33.
Table 34.
This register sets the acceleration value taken as a reference for the high-pass filter output.
When filter is turned on (at least one of FDS, HPen2, or HPen1 bit is equal to ‘1’) and HPM
bits are set to “01”, filter out is generated taking this value as a reference.
STATUS_REG (27h)
Table 35.
Table 36.
Ref7 - Ref0
ZYXOR
ZOR
YOR
XOR
ZYXDA
ZYXOR
Ref7
REFERENCE register
REFERENCE description
STATUS_REG register
STATUS_REG description
X, Y and Z axis data overrun. Default value: 0
(0: no overrun has occurred;
1: new data has overwritten the previous one before it was read)
Z axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the Z-axis has overwritten the previous one)
Y axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the Y-axis has overwritten the previous one)
X axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the X-axis has overwritten the previous one)
X, Y and Z axis new data available. Default value: 0
(0: a new set of data is not yet available; 1: a new set of data is available)
Reference value for high-pass filter. Default value: 00h.
Ref6
ZOR
Ref5
YOR
Doc ID 15094 Rev 3
XOR
Ref4
ZYXDA
Ref3
Ref2
ZDA
Ref1
YDA
LIS331DLH
Ref0
XDA

Related parts for STEVAL-MKI031V1