DC-ME-9210-NET Digi International, DC-ME-9210-NET Datasheet - Page 65

KIT JUMP START ME 9210 NET+OS 7

DC-ME-9210-NET

Manufacturer Part Number
DC-ME-9210-NET
Description
KIT JUMP START ME 9210 NET+OS 7
Manufacturer
Digi International
Series
Digi Connect ME®r
Type
MCU Moduler

Specifications of DC-ME-9210-NET

Contents
Board, Cables, CD, Digi JTAG Link Hardware Debugger, Documentation, Module, Power Supply
Data Rate
10 Mbps to 100 Mbps
Memory Type
SDRAM
Interface Type
RS-232, Ethernet
Operating Voltage
12 V
Operating Current
346 mA
Maximum Power Dissipation
825 mW
Operating Temperature Range
- 40 C to + 80 C
Board Size
36.7 mm x 19.05 mm
Data Bus Width
32 bit
Modulation
CCK, DBPSK, DQPSK
Product
Modules
Security
64/128 bit WEP, TKIP, WPA, WPA2
Silicon Manufacturer
Digi Intl
Kit Application Type
Communication & Networking
Application Sub Type
Embedded
Silicon Family Name
Digi Connect ME
Rohs Compliant
Yes
For Use With/related Products
Digi Connect ME 9210 Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
602-1136
65
Revision E
Revision D
Revision C
Revision B
Revision 90000631_G>90000897_A
Revision G
      
Changed schematics in appendix A to reflect correct measurements.
Added a new section labeled “Thermal Specifications” to the book. This section outlines
the temperature ranges at which the devices specified can still function properly.
Updates to schematics in Chapter 2.
Added/revised Module Pin-out table in Chapter 3.
Updated GPIO tables throughout book.
Fixed page numbers to make them correspond in PDF form.
Added components to Development Board schematics. (#19 and 20)
Added Connect ME 9210 related information.
Updated schematics in development board chapter to reflect 9210 changes.
Updated the Connectors: power and device interface section to say that pins 1 and 2 on the
connector are available if using Connect ME, not available if using Connect Wi-ME.
Updated the Embedded Module Connector table in Chapter 2 similarly.
Added tolerance information for dimension drawings
Updated Hard Reset section to clarify forcing the unit into hard reset

Related parts for DC-ME-9210-NET