6.5. Enabling and Using Watch Windows
The Debug Windows in the View menu are used to view and modify hardware registers. To view and modify
variables in code, the IDE provides Watch Windows. Just as with register debug windows, variables in the watch
windows are updated each time the device is halted. This section of the User’s Guide explains how to add a
variable to the watch window and modify the variable. In the F342DC_FeaturesDemo example code, the variable
Num_LED_Flashes is a counter that stores the number of times the LED blinks.
1. If the device is running, stop execution using the “Stop” button or use the Debug → Stop menu option.
2. In the File View on the left-hand side of the IDE, double-click on F342DC_FeaturesDemo.c to open the source
3. Scroll to the ADC0_ISR function and right-click on the variable “Num_LED_Flashes”. In the context menu that
4. Start and stop the device a few times. See that the value of the Num_LED_Flashes is incremented each time
5. When the device is halted, click on the value field in the watch window and change the value to 0. Then click the
6. Start and stop the device a few times to watch the variable increment starting at 0.
Changing the values of variables does not require recompiling the code and redownloading the firmware. At any
time, the device can be halted and the values of the variables can be changed. The firmware will continue
execution using the new values.
file.
appears, select “Add Num_LED_Flashes to Watch” and then choose “Default.” On the right-hand portion of
the IDE, the watch window appears and the variable is added. The current value of the variable is shown to the
right of the name.
the LED blinks.
Refresh button or select Debug → Refresh to write the new value to the device.