C8051F410-TB Silicon Laboratories Inc, C8051F410-TB Datasheet - Page 63

no-image

C8051F410-TB

Manufacturer Part Number
C8051F410-TB
Description
BOARD PROTOTYPING W/C8051F410
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F410-TB

Contents
Board
Processor To Be Evaluated
C8051F41x
Interface Type
USB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F410
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
5.4.
The ADC Programmable Window Detector continuously compares the ADC0 output registers to user-pro-
grammed limits, and notifies the system when a desired condition is detected. This is especially effective in
an interrupt-driven system, saving code space and CPU bandwidth while delivering faster system
response times. The window detector interrupt flag (AD0WINT in register ADC0CN) can also be used in
polled mode. The ADC0 Greater-Than (ADC0GTH, ADC0GTL) and Less-Than (ADC0LTH, ADC0LTL)
registers hold the comparison values. The window detector flag can be programmed to indicate when mea-
sured data is inside or outside of the user-programmed limits, depending on the contents of the ADC0
Less-Than and ADC0 Greater-Than registers.
Bits7–4: AD0PWR3–0: ADC0 Burst Power-Up Time.
Bits3–2: AD0TM1–0: ADC0 Tracking Mode Select Bits.
Bits1–0: AD0TK1–0: ADC0 Post-Track Time.
R/W
Bit7
Programmable Window Detector
For BURSTEN = 0:
ADC0 power state controlled by AD0EN.
For BURSTEN = 1 and AD0EN = 1;
ADC0 remains enabled and does not enter the low power state.
For BURSTEN = 1 and AD0EN = 0:
ADC0 enters the low power state as specified in Table 5.3 and Table 5.4 and is enabled
after each convert start signal. The Power Up time is programmed according to the following
equation:
00: Reserved.
01: ADC0 is configured to Post-Tracking Mode.
10: ADC0 is configured to Pre-Tracking Mode.
11: ADC0 is configured to Dual-Tracking Mode (default).
Post-Tracking time is controlled by AD0TK as follows:
00: Post-Tracking time is equal to 2 SAR clock cycles + 2 FCLK cycles.
01: Post-Tracking time is equal to 4 SAR clock cycles + 2 FCLK cycles.
10: Post-Tracking time is equal to 8 SAR clock cycles + 2 FCLK cycles.
11: Post-Tracking time is equal to 16 SAR clock cycles + 2 FCLK cycles.
AD0PWR
SFR Definition 5.6. ADC0TK: ADC0 Tracking Mode Select
R/W
Bit6
AD0PWR
=
Tstartup
---------------------- 1
R/W
Bit5
400ns
R/W
Bit4
or
Tstartup
Rev. 1.1
R/W
Bit3
AD0TM
=
R/W
Bit2
AD0PWR
C8051F410/1/2/3
R/W
Bit1
+
AD0TK
1
(bit addressable)
400ns
R/W
Bit0
SFR Address:
Reset Value
11111111
0xBA
63

Related parts for C8051F410-TB