R0E0200F1EMU00 Renesas Electronics America, R0E0200F1EMU00 Datasheet - Page 44

no-image

R0E0200F1EMU00

Manufacturer Part Number
R0E0200F1EMU00
Description
DEV EMULATOR E200 MAIN BODY
Manufacturer
Renesas Electronics America
Series
SuperH®r
Type
In-Circuit Emulatorr
Datasheet

Specifications of R0E0200F1EMU00

Contents
Emulator Board, Cables, Software and Documentation
For Use With/related Products
SH7080
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
The [Event Condition 11] dialog box is used to specify the count of [Event Condition 1] and
becomes a reset point when the sequential condition is specified.
Sequential Setting: Use the [Combination action(Sequential or PtoP)] dialog box to specify the
sequential condition and the start or end of performance measurement.
Table 3.9 Conditions to Be Set
Rev. 4.00 Feb. 18, 2009 Page 36 of 64
REJ10J1662-0400
Classification
[Ch1, 2, 3] list box
Item
Sets the sequential condition and the start or end of performance
measurement using Event Conditions 1 to 3 and 11.
Don’t care
Break: Ch3-2-1
Break: Ch3-2-1,
Reset point
Break: Ch2-1
Break: Ch2-1,
Reset point
I-Trace stop: Ch3-2-1 Halts acquisition of an internal trace when a
I-Trace stop: Ch3-2-1,
Reset point
I-Trace stop: Ch2-1
I-Trace stop: Ch2-1,
Reset point
Sets no sequential condition or the start or end of
Description
performance measurement.
Breaks when a condition is satisfied in the order of
Event Condition 3, 2, 1.
Breaks when a condition is satisfied in the order of
Event Condition 3, 2, 1.
Enables the reset point of Event Condition 11.
Breaks when a condition is satisfied in the order of
Event Condition 2, 1.
Breaks when a condition is satisfied in the order of
Event Condition 2, 1.
Enables the reset point.
condition is satisfied in the order of Event Condition
3, 2, 1.
Halts acquisition of an internal trace when a
condition is satisfied in the order of Event Condition
3, 2, 1.
Enables the reset point.
Halts acquisition of an internal trace when a
condition is satisfied in the order of Event Condition
2, 1.
Halts acquisition of an internal trace when a
condition is satisfied in the order of Event Condition
2, 1.
Enables the reset point.

Related parts for R0E0200F1EMU00