HSC-ADC-EVALA-DC Analog Devices Inc, HSC-ADC-EVALA-DC Datasheet - Page 4

KIT EVAL FOR DUAL ADC/CONV

HSC-ADC-EVALA-DC

Manufacturer Part Number
HSC-ADC-EVALA-DC
Description
KIT EVAL FOR DUAL ADC/CONV
Manufacturer
Analog Devices Inc
Datasheets

Specifications of HSC-ADC-EVALA-DC

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
AN-905
QUICK START FOR ADC EVALUATION
With VisualAnalog, it is easy to bypass the canvas interface and
begin ADC evaluation immediately. To begin interfacing to a
particular ADC right away, use the following steps:
1. Connect and power the evaluation board, ADC data capture
2. Connect the ADC data capture board to the computer
3.
4.
board, and any other required board used for data transfer.
You can also supply the required clock and input signals to
the ADC evaluation board.
with a high speed USB cable. If a driver installation dialog
appears, as happens when using the ADC data capture
board for the first time, proceed through the dialog steps.
If the Hardware Wizard appears (see Figure 2), follow the
instructions to install the software automatically. This allows
Windows to complete the driver installation process.
Start VisualAnalog. For more information, see the
VISUALANALOG Software section.
The start-up form now appears. If an ADC was connected
using the preceding steps, VisualAnalog attempts to detect
it and selects the canvas template that supports the ADC
on the start-up form. Note that the ADC must support
SPI® functionality for the program to autodetect. If the
ADC does not support SPI, or if the program does not
detect the ADC for any reason, manually select the tem-
plate. See the Using the Start-Up Form section for more
information.
Figure 2. Hardware Wizard
Rev. 0 | Page 4 of 40
5.
6.
A Graph form should appear with the FFT results. If the graph
does not appear, it is possible there was an error during
processing. Check the board connection and try again. If this
does not fix the problem, expand the main form and check the
canvas settings. For more information, see the Using the Main
Form and the Components Overview sections.
7. The main form appears in collapsed mode with your canvas
Select the FFT icon and click Open.
If you have an HSC-ADC-EVALC data capture board, a
dialog box that asks for permission to configure the on­
board FPGA may appear. If you prefer to use the current
FPGA configuration, click No to bypass configuration.
Otherwise, click Yes to configure the FPGA. See the Using
the Start-Up Form section for more information.
open and selected. Click Update to run the canvas.
Figure 4. FPGA Configuration Dialog
Figure 3. New Canvas Form
Figure 5. Update Button

Related parts for HSC-ADC-EVALA-DC