Main Purpose
Interface, GPIO Expander
Embedded
No
Utilized Ic / Part
STMPE2403
Primary Attributes
8/16/24-Bit 24-Port GPIO Expander over I2C
Secondary Attributes
3 8-Bit PWM Output for LEDs, Keyboard Matrix Scan, Special Key Support
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-8206

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-TCS003V1
Manufacturer:
ST
0
PWM controller
11.2
42/63
PWM Control and Status Register (PWMCS)
Table 40. Bit description
Reset Value
Read/Write
Bits
0
1
2
3
4
5
6
7
Bit
ExtSel
Name
ExtEn
EN0
EN1
EN2
II0
II1
II2
ExtSel
RW
PWM Channel 0 Enable bit.
‘1’ – Enable the PWM Channel 0
‘0’ – Reset the PWM Channel 0. Only when the PWM channel is in reset state,
the stream of commands can be written into its data port, which in this case is
PWM_Command_Channel_0.
PWM Channel 1 Enable bit.
‘1’ – Enable the PWM Channel 1
‘0’ – Reset the PWM Channel 1. Only when the PWM channel is in reset state,
the stream of commands can be written into its data port, which in this case is
PWM_Command_Channel_1.
PWM Channel 2 Enable bit.
‘1’ – Enable the PWM Channel 2
‘0’ – Reset the PWM Channel 2. Only when the PWM channel is in reset state,
the stream of commands can be written into its data port, which in this case is
PWM_Command_Channel_2.
PWM Invalid Instruction Status bit for PWM Channel 0
‘0’ – No invalid command encountered during the instruction execution.
‘1’ – Invalid command encountered and this puts the PWM Channel 0 into reset
state.
PWM Invalid Instruction Status bit for PWM Channel 1
‘0’ – No invalid command encountered during the instruction execution.
‘1’ – Invalid command encountered and this puts the PWM Channel 1 into reset
state.
PWM Invalid Instruction Status bit for PWM Channel 2
‘0’ – No invalid command encountered during the instruction execution.
‘1’ – Invalid command encountered and this puts the PWM Channel 2 into reset
state.
External Trigger Enable
‘0’ – External triggering function is disabled
‘1’ – External triggering function is enabled
If enabled, GPIO-15 is used as trigger input/output
External Trigger Direction Selection
‘0’ – Active high external trigger input
‘1’ – Active low external trigger output
7
0
ExtEn
RW
6
0
II2
R
5
0
II1
R
4
0
Description
II0
R
3
0
EN2
RW
2
0
EN1
RW
1
0
STMPE2403
EN0
RW
0
0