Datasheets

Specifications of HS7727KCI02H

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
10. When the [Physical] option is selected in the [Memory area] group box in the [General] page
11. When the [Virtual] option is selected in the [Memory area] group box in the [General] page of
12. An address (physical address) to which a BREAKPOINT is set is determined when the
13. If an address of a BREAKPOINT cannot be correctly set in the ROM or flash memory area, a
2.2.6
1. When [Go to cursor], [Step In], [Step Over], or [Step Out] is selected, the settings of Break
2. Break Condition 2 is disabled when an instruction to which a BREAKPOINT has been set is
3. When a Break Condition is satisfied, emulation may stop after two or more instructions have
22
However, for addresses out of the range of the VP_MAP table, the address to which a
BREAKPOINT is set depends on the SH7727 MMU status during command input. Even
when the VP_MAP table is modified after BREAKPOINT setting, the address translated when
the BREAKPOINT is set valid.
of the [Configuration] dialog box, a BREAKPOINT is set to a physical address. A
BREAKPOINT is set after disabling the SH7727 MMU upon program execution. After
setting, the MMU is returned to the original state. When a break occurs at the corresponding
virtual address, the cause of termination displayed in the status bar and the [Output] window is
ILLEGAL INSTRUCTION, not BREAKPOINT.
the [Configuration] dialog box, a BREAKPOINT is set to a virtual address. A BREAKPOINT
is set after enabling the SH7727 MMU upon program execution. After setting, the MMU is
returned to the original state. When an ASID value is specified, the BREAKPOINT is set to
the virtual address corresponding to the ASID value. The emulator sets the BREAKPOINT
after rewriting the ASID value to the specified value, and returns the ASID value to its original
value after setting. When no ASID value is specified, the BREAKPOINT is set to a virtual
address corresponding to the ASID value at command input.
BREAKPOINT is set. Accordingly, even if the VP_MAP table is modified after
BREAKPOINT setting, the BREAKPOINT address remains unchanged. When a
BREAKPOINT is satisfied with the modified address in the VP_MAP table, the cause of
termination displayed in the status bar and the [Output] window is ILLEGAL INSTRUCTION,
not BREAKPOINT.
mark l will be displayed in the [BP] area of the address on the [Editor] or [Disassembly]
window by refreshing the [Memory] window, etc. after Go execution. However, no break will
occur at this address. When the program halts with the break condition, the mark l
disappears.
Condition 2 are disabled.
executed. Accordingly, do not set a BREAKPOINT to an instruction which satisfies Break
Condition 2.
been executed.
Notes on Setting the [Break Condition] Dialog Box and the BREAKCONDITION_
SET Command