EPSILON5-UPG15 Equinox Technologies, EPSILON5-UPG15 Datasheet - Page 64

no-image

EPSILON5-UPG15

Manufacturer Part Number
EPSILON5-UPG15
Description
UPGRADE EPSILON ATMEL AT91SAM7
Manufacturer
Equinox Technologies
Series
Epsilon5r
Type
Upgrade Kitr
Datasheet

Specifications of EPSILON5-UPG15

For Use With/related Products
Epsilon5
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3.6 Programmer and Target System are independently powered
3.6.1 Overview
In this scenario, the programmer is powered from a completely independent supply to the Target
System. The Jumper J9 is NOT fitted which isolates the Target Vcc voltage (V_TVCC) from CON1
VIN. This means that the programmer is always powered up.
Explanation of operation:
3.6.2 Hardware Setup - Programmer and Target System independently
powered
Warning!
EPSILON5 MKII Programmer - User Guide V1.12 – 1
The programmer is always powered ON
Jumper J9 is removed
The Target Power Supply should be switched OFF before the ISP cable is plugged into it
The programmer does not draw any current from the Target System during programming
When programming is complete, the Target System should be powered OFF and then the ISP
cable removed
The external voltage applied to the programmer via CON1 must be between 3.1 and 5.0V !
The voltage applied to the programmer via the ISP cable must be between 3.1 and 5.0V as
this voltage is used to drive the programmer I/O Stage. A 6V2 5W zener diode is internally
connected across the programmer supply to protect against over-voltage.
J9 must be removed to avoid contention between the two power supplies.
st
August 2007
53

Related parts for EPSILON5-UPG15