H5CX-A11-N AC100-240 Omron, H5CX-A11-N AC100-240 Datasheet - Page 27

RELAY TIMER DGTL SPDT 100/240VAC

H5CX-A11-N AC100-240

Manufacturer Part Number
H5CX-A11-N AC100-240
Description
RELAY TIMER DGTL SPDT 100/240VAC
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-A11-N AC100-240

Mounting Type
Socket
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Termination Style
11 Pin Socketable
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Timing Range
0.001 s to 9999 Hrs
Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Display Type
4 Digit LCD Backlight
Product
Digital Timer
Time Range
0.001s-9999hrs
Power Consumption
6.2VA
Reset Time
20ms
Signal Input Type
PNP/NPN
Supply Voltage Max
240VAC
Character Size
11.5mm
Switch Function
SPDT
Supply Voltage Min
100VAC
Rohs Compliant
Yes
No. Of Digits / Alpha
4
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H5CXA11NAC100240
Z2998
From previous
page
To previous
page
*1
Set value
upper limit 1
Set value
upper limit 2
Key protect
level
Output ON
count alarm
set value/
monitor value
Set the digits for the set value limit using the corresponding
Set the digits for the set value limit using the corresponding
Set the key protect level using the
kp-1
(KP-1)
(1)
(1)
1
1
9999
9999
(9999)
(9999)
kp-2
(KP-2)
kp-3
(KP-3)
*1. Set the digits for the output ON alarm set value using the corresponding
• Models without Instantaneous Contact Outputs
• Models with Instantaneous Contact Outputs
kp-4
(KP-4)
keys.
keys.
Output ON
count alarm
set value
Output ON
count monitor
value
Instantaneous
output 1
(OUT1) ON
count alarm
set value
Instantaneous
output 2
(OUT2) ON
count alarm
set value
Instantaneous
output 1
(OUT1) ON
count monitor
value
Instantaneous
output 2
(OUT2) ON
count monitor
value
kp-5
(KP-5)
kp-6
(KP-6)
Note: The monitor value is only displayed.
Note: The monitor value is only displayed.
Note: The monitor value is only displayed.
(0 x 1000 times)
(0 x 1000 times)
(0 x 1000 times)
keys.
keys.
It cannot be set.
It cannot be set.
It cannot be set.
0
0
0
H5CX-A@-N/-L@-N
kp-7
(KP-7)
~
~
~
(9999 x 1000 times)
(9999 x 1000 times)
(9999 x 1000 times)
9999
9999
9999
Twin Timer
27

Related parts for H5CX-A11-N AC100-240