H5CX-A11-N AC100-240 Omron, H5CX-A11-N AC100-240 Datasheet - Page 31

RELAY TIMER DGTL SPDT 100/240VAC

H5CX-A11-N AC100-240

Manufacturer Part Number
H5CX-A11-N AC100-240
Description
RELAY TIMER DGTL SPDT 100/240VAC
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-A11-N AC100-240

Mounting Type
Socket
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Termination Style
11 Pin Socketable
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Timing Range
0.001 s to 9999 Hrs
Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Display Type
4 Digit LCD Backlight
Product
Digital Timer
Time Range
0.001s-9999hrs
Power Consumption
6.2VA
Reset Time
20ms
Signal Input Type
PNP/NPN
Supply Voltage Max
240VAC
Character Size
11.5mm
Switch Function
SPDT
Supply Voltage Min
100VAC
Rohs Compliant
Yes
No. Of Digits / Alpha
4
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H5CXA11NAC100240
Z2998
Timer/Twin Timer Selection Mode (Function Selection)
Select whether the H5CX is used as a timer or a twin timer in timer/twin timer selection mode.
The H5CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be
confirmed using the front display.
*1. When the mode is changed to timer/twin timer selection mode, the present value is reset and output turns OFF.
*2. Setting changes made in timer/twin timer selection mode are enabled when the mode is changed to run mode.
Timing operation is not performed in timer/twin timer selection mode.
If settings are changed, the HC5X is automatically reset (present value initialized, output turned OFF).
*2
Power ON
1 s min.
+
1
*1
Timer/Twin
timer selection
DIP switch
monitor
Caution
Select either
Note: The H5CX is factory-set for timer operation.
Confirm the status of DIP switch pins 1 to 8 using the
Note: 1. This display is not supported with H5CX-L8@-N.
To change the mode to timer/twin timer selection mode,
hold down the
down. The
key is pressed first, the mode will not change.
OFF
ON
2. This display is only possible when DIP switch pin 1 (DIP switch settings
enable/disable) is set to ON (enable).
1 2 3 4 5 6 7 8
Example
keys.
tim
1
key must be pressed before the key. If the
timer operation or
1
key for 1 s min. with the
Key
twn
twin timer operation using the
key held
H5CX-A@-N/-L@-N
Indicates that DIP switch pin 8 is ON.
Indicates that DIP switch pin 7 is OFF.
Indicates that DIP switch pin 6 is ON.
Indicates that DIP switch pin 5 is OFF.
Indicates that DIP switch pin 4 is ON.
Indicates that DIP switch pin 3 is OFF.
Indicates that DIP switch pin 2 is ON.
Indicates that DIP switch pin 1 is ON.
keys.
1
Key
31