C8051F504-IM Silicon Laboratories Inc, C8051F504-IM Datasheet - Page 214

IC 8051 MCU 32K FLASH 48-QFN

C8051F504-IM

Manufacturer Part Number
C8051F504-IM
Description
IC 8051 MCU 32K FLASH 48-QFN
Manufacturer
Silicon Laboratories Inc
Series
C8051F50xr
Datasheets

Specifications of C8051F504-IM

Program Memory Type
FLASH
Program Memory Size
32KB (32K x 8)
Package / Case
48-QFN
Mfg Application Notes
LIN Bootloader AppNote
Core Processor
8051
Core Size
8-Bit
Speed
50MHz
Connectivity
EBI/EMI, SMBus (2-Wire/I²C), CAN, LIN, SPI, UART/USART
Peripherals
POR, PWM, Temp Sensor, WDT
Number Of I /o
40
Ram Size
4.25K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.25 V
Data Converters
A/D 32x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Processor Series
C8051F5x
Core
8051
Data Bus Width
8 bit
Data Ram Size
4.25 KB
Interface Type
I2C/SPI/UART
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
40
Number Of Timers
4
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051F500DK
Minimum Operating Temperature
- 40 C
On-chip Adc
32-ch x 12-bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1527 - KIT DEV FOR C8051F50X
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1519-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F504-IM
Manufacturer:
Silicon Labs
Quantity:
135
C8051F50x/F51x
LIN Register Definition 21.7. LIN0ERR: LIN0 Error Register
Indirect Address = 0x0A
214
Name
Reset
7:5
Bit
Type
4
3
2
1
0
Bit
BITERR
SYNCH
Unused
Name
PRTY
TOUT
CHK
R
7
0
Read = 000b; Write = Don’t Care
Synchronization Error Bit (slave mode only).
0: No error with the SYNCH FIELD has been detected.
1: Edges of the SYNCH FIELD are outside of the maximum tolerance.
Parity Error Bit (slave mode only).
0: No parity error has been detected.
1: A parity error has been detected.
Timeout Error Bit.
0: A timeout error has not been detected.
1: A timeout error has been detected. This error is detected whenever one of the fol-
lowing conditions is met:
Checksum Error Bit.
0: Checksum error has not been detected.
1: Checksum error has been detected.
Bit Transmission Error Bit.
0: No error in transmission has been detected.
1: The bit value monitored during transmission is different than the bit value sent.
R
6
0
The master is expecting data from a slave and the slave does not respond.
The slave is expecting data but no data is transmitted on the bus.
A frame is not finished within the maximum frame length.
The application does not set the DTACK bit (LIN0CTRL.4) or STOP bit
(LIN0CTRL.7) until the end of the reception of the first byte after the identifier.
R
5
0
SYNCH
Rev. 1.2
R
4
0
Function
PRTY
R
3
0
TOUT
R
2
0
CHK
R
1
0
BITERR
R
0
0