Specifications of XR16L788IQ-F

Number Of Channels
8
Package / Case
100-BQFP
Features
*
Fifo's
64 Byte
Protocol
RS485
Voltage - Supply
2.97 V ~ 5.5 V
With Auto Flow Control
Yes
With Irda Encoder/decoder
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
Mounting Type
Surface Mount
Data Rate
6.25 Mbps
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.97 V
Supply Current
5 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3.3 V or 5 V
No. Of Channels
8
Uart Features
Tx/Rx FIFO Counters
Supply Voltage Range
2.97V To 5.5V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
QFP
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
1016-1284

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR16L788IQ-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
XR16L788IQ-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
XR16L788
HIGH PERFORMANCE 2.97V TO 5.5V OCTAL UART
This register provides the status of data transfers between the UART and the host. If IER bit-2 is set to a logic
1, an LSR interrupt will be generated immediately when any character in the RX FIFO has an error (parity,
framing, overrun, break).
LSR[0]: Receive Data Ready Indicator
LSR[1]: Receiver Overrun Flag
LSR[2]: Receive Data Parity Error Flag
LSR[3]: Receive Data Framing Error Flag
LSR[4]: Receive Break Flag
LSR[5]: Transmit Holding Register Empty Flag
This bit is the Transmit Holding Register Empty indicator. This bit indicates that the transmitter is ready to
accept a new character for transmission. In addition, this bit causes the UART to issue an interrupt to the host
when the THR interrupt enable is set. The THR bit is set to a logic 1 when the last data byte is transferred from
the transmit holding register to the transmit shift register. The bit is reset to logic 0 concurrently with the data
loading to the transmit holding register by the host. In the FIFO mode this bit is set when the transmit FIFO is
empty; it is cleared when at least 1 byte is written to the transmit FIFO.
LSR[6]: Transmit Shift Register Empty Flag
This bit is the Transmit Shift Register Empty indicator. This bit is set to a logic 1 whenever the transmitter goes
idle. It is set to logic 0 whenever either the THR or TSR contains a data character. In the FIFO mode this bit is
set to one whenever the transmit FIFO and transmit shift register are both empty.
LSR[7]: Receive FIFO Data Error Flag
This register provides the current state of the modem interface signals, or other peripheral device that the
UART is connected. Lower four bits of this register are used to indicate the changed information. These bits
are set to a logic 1 whenever a signal from the modem changes state. These bits may be used as general
purpose inputs/outputs when they are not used with modem signals.
4.8
4.9
Logic 0 = No data in receive holding register or FIFO (default).
Logic 1 = Data has been received and is saved in the receive holding register or FIFO.
Logic 0 = No overrun error (default).
Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register
is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into
the FIFO, therefore the data in the FIFO is not corrupted by the error.
Logic 0 = No parity error (default).
Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR.
Logic 0 = No framing error (default).
Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR.
Logic 0 = No break condition (default).
Logic 1 = The receiver received a break signal (RX was a logic 0 for one character frame time). In the FIFO
mode, only one break character is loaded into the FIFO. The break indication remains until the RX input
returns to the idle condition, “mark” or logic 1.
Logic 0 = No FIFO error (default).
Logic 1 = An indicator for the sum of all error bits in the RX FIFO. At least one parity error, framing error or
break indication is in the FIFO data. This bit clears when there is no more error(s) in the FIFO.
Line Status Register (LSR) - Read Only
Modem Status Register (MSR) - Read Only