XBIB-U Digi International/Maxstream, XBIB-U Datasheet - Page 56

no-image

XBIB-U

Manufacturer Part Number
XBIB-U
Description
BOARD USB ZIGBEE MOD PRO
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XBIB-U

Design Resources
XBIB-U Shematic
Accessory Type
Interface Board
For Use With/related Products
XBee and XBee Pro Radios
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XBIB-U-DEV
Manufacturer:
DIGI
Quantity:
20 000
XBee/XBee‐PRO™ OEM RF Modules ‐ 802.15.4 ‐ v1.xAx [2007.05.031]
Identifies the UART data frame for the host to
correlate with a subsequent ACK (acknowledgement).
If set to ‘0’, no response is sent.
Identifies the UART data frame for the host to
correlate with a subsequent ACK (acknowledgement).
If set to ‘0’, no response is requested.
AT Command
AT Command - Queue Parameter Value
API Identifier Value: 0x08
The “AT Command” API type allows for module parameters to be queried or set. When using this
command ID, new parameter values are applied immediately. This includes any register set with
the “AT Command - Queue Parameter Value” (0x09) API type.
Figure 3‐05. AT Command Frames
Figure 3‐06. Example: API frames when reading the DL parameter value of the module.
Start Delimiter
Figure 3‐07. Example: API frames when modifying the DL parameter value of the module.
API Identifier Value: 0x09
This API type allows module parameters to be queried or set. In contrast to the “AT Command” API
type, new parameter values are queued and not applied until either the “AT Command” (0x08) API
type or the AC (Apply Changes) command is issued. Register queries (reading parameter values)
are returned immediately.
Figure 3‐08. AT Command Frames 
Start Delimiter
* Length [Bytes] = API Identifier + Frame ID + AT Command
** “R” value was arbitrarily selected.
© 2007 MaxStream, Inc.
* Length [Bytes] = API Identifier + Frame ID + AT Command + Parameter Value
** “M” value was arbitrarily selected.
Start Delimiter
Start Delimiter
Byte 1
Byte 1
0x7E
0x7E
0x7E
0x7E
Frame ID (Byte 5)
Frame ID (Byte 5)
(Note that frames are identical to the “AT Command” API type except for the API identifier.)
0x00 0x04
0x00 0x08
Bytes 2-3
Bytes 2-3
MSB
MSB
Length*
Length*
Length
Length
LSB
LSB
API Identifier
API Identifier
0x08
0x09
API Identifier
API Identifier
API-specific Structure
API-specific Structure
Byte 4
Byte 4
0x08
0x08
Frame Data
Frame Data
Identifier-specific Data
Command Name - Two
ASCII characters that
identify the AT Command.
Identifier-specific Data
Command Name - Two
ASCII characters that
identify the AT Command.
AT Command (Bytes 6-7)
AT Command (Bytes 6-7)
Frame ID**
Frame ID**
0x4D (M)
cmdData
0x52 (R)
cmdData
Byte 5
Byte 5
Checksum
Checksum
1 Byte
1 Byte
0x44 (D) 0x4C (L)
0x44 (D) 0x4C (L)
AT Command
AT Command
Bytes 6-7
Bytes 6-7
If present, indicates the requested parameter
value to set the given register.
If no characters present, register is queried.
If present, indicates the requested parameter
value to set the given register.
If no characters present, register is queried.
Parameter Value (Byte(s) 8-n)
Parameter Value (Byte(s) 8-n)
Chapter 3 ‐ RF Module Configuration
Checksum
Parameter Value
0x00000FFF
Byte 8
0x15
Bytes 8-11
Checksum
Byte 12
0x0C
     56