LMH2100TM/NOPB National Semiconductor, LMH2100TM/NOPB Datasheet - Page 25

IC LOG DETECTOR 4GHZ 40DB 6MSMD

LMH2100TM/NOPB

Manufacturer Part Number
LMH2100TM/NOPB
Description
IC LOG DETECTOR 4GHZ 40DB 6MSMD
Manufacturer
National Semiconductor
Datasheet

Specifications of LMH2100TM/NOPB

Frequency
50MHz ~ 4GHz
Rf Type
Cellular, W-CDMA, CDMA, GSM, UMTS
Input Range
-45dBm ~ -5dBm
Accuracy
0.5dB
Voltage - Supply
2.7 V ~ 3.3 V
Current - Supply
9.2mA
Package / Case
6-UFBGA
Pin Count
6
Screening Level
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LMH2100TMTR
The mean drift error represents the reproducible - systematic
- part of the error, while the mean ± 3 sigma limits represent
the combined systematic plus random error component. Ob-
viously the drift error must be zero at calibration temperature
T
in the estimator, the total drift error becomes equal to only the
random component, as illustrated in the graph at the right of
Figure 8. A significant reduction of the temperature drift error
can be achieved in this way only if:
It is essential for the effectiveness of the temperature com-
pensation to assign the appropriate value to the temperature
sensitivity S
determine this parameter:
Also for the first method, the accuracy of the extracted tem-
perature sensitivity increases when the number of measure-
0
. If the systematic component of the drift error is included
The systematic component is significantly larger than the
random error component (otherwise the difference is
negligible).
The operating temperature is measured with sufficient
accuracy.
Determination of a single value to be used over the entire
operating temperature range.
Division of the operating temperature range in segments
and use of separate values for each of the segments.
1
. Two different approaches can be followed to
FIGURE 9. Temperature Drift Error without and with Temperature Compensation
FIGURE 8. Elimination of the Systematic Component from the Temperature Drift
30014052
25
ment temperatures increases. Linear regression to tempera-
ture can then be used to determine the two parameters of the
linear model for the temperature drift error: the first order tem-
perature sensitivity S
value for the power estimate at T
to achieve an overall - over all temperatures - minimum error,
the room temperature drift error in the model can be non-zero
at the calibration temperature (which is not in agreement with
the strict definition).
The second method does not have this drawback but is more
complex. In fact, segmentation of the temperature range is a
form of higher-order temperature compensation using only a
first-order model for the different segments: one for temper-
atures below 25°C, and one for temperatures above 25°C.
The mean (or typical) temperature sensitivity is the value to
be used for compensation of the systematic drift error com-
ponent. Figure 9 shows the temperature drift error without and
with temperature compensation using two segments. With
compensation the systematic component is completely elim-
inated; the remaining random error component is centered
around zero. Note that the random component is slightly larg-
er at −40°C than at 85°C.
1
30014065
and the best-fit (room temperature)
0
: F
DET
[V
OUT
(T),T
30014095
www.national.com
0
]. Note that

Related parts for LMH2100TM/NOPB