10054542-001LF FCI, 10054542-001LF Datasheet

no-image

10054542-001LF

Manufacturer Part Number
10054542-001LF
Description
CONN RECEPT SAS 22POS VERT PCB
Manufacturer
FCI
Datasheet

Specifications of 10054542-001LF

Connector Style
Receptacle
Connector Type
SAS
Number Of Positions
22
Mounting Type
Through Hole
Termination
Solder
Contact Finish
Gold
Contact Finish Thickness
3µin (0.08µm)
Product
SAS Connectors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
609-1549
NUMBER
TITLE
Copyright
Form E-3334
Rev F
GS-12-239
FCI
Backpanel Header
AirMax VS
TYPE
®
Connector System, press-fit products
PRODUCT SPECIFICATION
AirMax VS
Backpanel Receptacle
®
Coplanar
Connector System
Orthogonal Header and Receptacle
PDM: Rev:F
STATUS:
PAGE
AUTHORIZED BY
STATUS
Tan Chen Hong
Released
1 of 11
UNRESTRICTED
Printed: Oct 04, 2008
REVISION
DATE
GS-01-001
30 Sep 08
F
.

Related parts for 10054542-001LF

10054542-001LF Summary of contents

Page 1

... NUMBER TYPE GS-12-239 TITLE ® AirMax VS Connector System, press-fit products Backpanel Header Copyright FCI Form E-3334 Rev F PRODUCT SPECIFICATION ® AirMax VS Connector System Backpanel Receptacle Coplanar Orthogonal Header and Receptacle PDM: Rev:F PAGE REVISION AUTHORIZED BY DATE Tan Chen Hong 30 Sep 08 STATUS ...

Page 2

... TABLE OF CONTENTS: 1.0 OBJECTIVE ........................................................................................................................ 3 2.0 SCOPE ................................................................................................................................ 3 3.0 APPLICABLE DOCUMENTS .............................................................................................. 3 3.1 FCI Specifications ............................................................................................................. 3 3.2 Other Standards and Specifications ................................................................................. 3 3.3 FCI Product Qualification Test reports.............................................................................. 3 4.0 REQUIREMENTS ................................................................................................................. 3 4.1 Materials............................................................................................................................. 3 4.2 Visual Examination of Product ........................................................................................... 3 5.0 ELECTRICAL CHARACTERISTICS ..................................................................................... 4 5.1 Low Level Contact Resistance........................................................................................... 4 5.2 Insulation Resistance ......................................................................................................... 4 5 ...

Page 3

... APPLICABLE DOCUMENTS 3.1 FCI Specifications - Applicable FCI product customer drawings - FCI Application Specification GS-20-035 (AirMax VS 3.2 Other Standards and Specifications - UL94V-O: Test for Flammability of Plastic Materials in Devices and Appliances - EIA 364: Electrical Connector/Socket Test Procedures Including Environmental Classifications - GR-1217-CORE: Telcordia Specification “Generic Requirements for Separable Electrical Connectors” ...

Page 4

... Thermocouple location: mechanically attached to the base of the header mating contacts c. Copper trace weight Quantity and location of thermocouples interior column at positions and outside column at positions and I) The temperature rise above ambient shall not exceed 30 degrees C with all contacts powered at 0.5A. Copyright FCI Form E-3334 Rev F PRODUCT SPECIFICATION o C PDM: Rev:F PAGE ...

Page 5

... Perform in accordance with EIA 364-05B. Fully populated connectors shall be applied to test boards with minimum, maximum, and nominal size plated through holes (as defined in Table 2) using an electric application press and FCI recommended application tooling. The following details shall apply: a. Force to insert one straight or right angle header pin maximum b ...

Page 6

... Un-mated backpanel connectors are to be exposed to gas mixture for 10 days, then mated and exposed for an additional 10 days. Case 2: Coplanar Applications Each connector gender exposed to gas mixture in the unmated condition for 10 days, then mated to an unexposed connector for a 10 day additional gas exposure and the remainder of the test. Copyright FCI Form E-3334 Rev F PRODUCT SPECIFICATION o C ...

Page 7

... Perform in accordance with Telcordia GR-1217-CORE, November 1995, Section 9.1.3.3 paragraph 7. The mated connectors shall be subjected to an interface disturbance that consists of slightly unmating the sample approximately 0.10 mm (0.004 inch). The sample is then reseated and measurements are made. Copyright FCI Form E-3334 Rev F PRODUCT SPECIFICATION ...

Page 8

... A significant change is made to the manufacturing process, which impacts the product form, fit or function significant event occurs during production or end use requiring corrective action to be taken relative to the product design or manufacturing process. Copyright FCI Form E-3334 Rev F PRODUCT SPECIFICATION PDM: Rev:F ...

Page 9

... The largest version of each product configuration is exposed to the entire qualification program (groups 1-7). Product extensions using the same design, but fewer rows are exposed to test group P only for design verification. Copyright FCI Form E-3334 Rev F PRODUCT SPECIFICATION Table 1: Qualification Test Matrix ...

Page 10

... Three of the backpanel test boards are to be back-drilled to a depth of 0.8mm (Test Group 5 / Backpanel Application only) 2. The largest version of each product configuration is exposed to the entire qualification program (groups 1-7). Product extensions using the same design, but fewer rows are exposed to test group P only for design verification. Copyright FCI Form E-3334 Rev F PRODUCT SPECIFICATION P ...

Page 11

... Increased min un-mating force to 0.15H in sec 6.1; Changed vibration sweep cycle time from 20 min to 15 min in sec 7.5c; Added “200 total mating cycles” to sec 7.7a Updated FCI logo; added details related to coplanar and backpanel C all header product configurations; added test group P to table 1 2,3,6,7, D ...