10054542-001LF FCI, 10054542-001LF Datasheet - Page 8

no-image

10054542-001LF

Manufacturer Part Number
10054542-001LF
Description
CONN RECEPT SAS 22POS VERT PCB
Manufacturer
FCI
Datasheet

Specifications of 10054542-001LF

Connector Style
Receptacle
Connector Type
SAS
Number Of Positions
22
Mounting Type
Through Hole
Termination
Solder
Contact Finish
Gold
Contact Finish Thickness
3µin (0.08µm)
Product
SAS Connectors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
609-1549
8.0
NUMBER
TITLE
Copyright
Form E-3334
Rev F
8.1
8.2
8.3
8.4
8.5
8.6
QUALITY ASSURANCE PROVISIONS
GS-12-239
FCI
Equipment Calibration
All test equipment and inspection facilities used in the performance of any test shall be maintained in a
calibration system in accordance with ISO 9000.
Inspection Conditions
Unless otherwise specified herein, all inspections shall be performed under the following ambient
conditions:
a. Temperature: 25 ± 5°C
b. Relative humidity: 20% to 80%
c. Barometric pressure: Local ambient
Sample Quantity and Description
The test sequences for qualification testing and connector sample sizes for each are shown in Table 1.
The number of readings is specified in the description for each test.
Acceptance
Electrical and mechanical requirements placed on test samples as indicated in the sections of this
specification shall be established from test data using appropriate statistical techniques or shall otherwise
be customer specified, and all samples tested in accordance with the product specification shall meet the
stated requirements.
Failures attributed to equipment, test set-up or operator error shall not disqualify the product. If product
failure occurs, corrective action shall be taken and samples resubmitted for qualification.
Qualification Testing
Qualification testing shall be performed on sample units with equipment and procedures normally used in
production. The test sequences are shown in Table 1.
Re-Qualification Testing
If any of the following conditions occur, the responsible product engineer shall initiate re-qualification
testing consisting of all applicable parts of the qualification test program as shown in Table 1.
a. A significant design change is made to the existing product, which impacts the product form, fit or
b. A significant change is made to the manufacturing process, which impacts the product form, fit or
c. A significant event occurs during production or end use requiring corrective action to be taken relative
AirMax VS
function. Examples of significant changes shall include, but not be limited to, changes in the plating,
material composition or thickness, contact force, pin/contact surface geometry, insulator or housing
design, pin/contact base material or pin/contact lubrication.
function.
to the product design or manufacturing process.
TYPE
®
Connector System, press-fit products
PRODUCT SPECIFICATION
PDM: Rev:F
STATUS:
PAGE
AUTHORIZED BY
STATUS
Tan Chen Hong
Released
8 of 11
UNRESTRICTED
Printed: Oct 04, 2008
REVISION
DATE
GS-01-001
30 Sep 08
F
.

Related parts for 10054542-001LF