WS02-CXPC1-EV2.0 Omron, WS02-CXPC1-EV2.0 Datasheet

Development Software

WS02-CXPC1-EV2.0

Manufacturer Part Number
WS02-CXPC1-EV2.0
Description
Development Software
Manufacturer
Omron
Datasheet

Specifications of WS02-CXPC1-EV2.0

Rohs Compliant
NA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
WS02CXPC1EV20
The SRM1’s high-speed distributed I/O
controller is a revolutionary design in PLC
control. The SRM1 places all the processing
power and control in the ultra compact master
unit and allows you to distribute up to 256
points of I/O via a twisted pair network. You
can create a distributed I/O network with up to
32 nodes at distances up to 500 meters away.
This allows for reduced cabling costs, in-
creased flexibility, lower system costs, and
optimum efficiency when I/O has to be located
away from the CPU.
H
H
H
H
H
H
H
Basic Configuration
Distributed I/O Controller
Host device
Distributed I/O system supports up to 256
I/O points
SRM1 master communicates with up to 32
nodes at up to 500 meters away
Twisted pair network allows easy addition of
devices and reduces cabling costs
High-speed communications at up to
750 kbps
Multiple remote I/O options including
discrete and analog I/O devices
4k Program memory; 2 k Data memory
UL/CSA/CE approvals
SRM1
Peripheral
device
Slave
R
CompoBus/S Communications Cable
32 Slaves max.
Slave
Slave
Terminator
SRM1
uC
1

Related parts for WS02-CXPC1-EV2.0

WS02-CXPC1-EV2.0 Summary of contents

Page 1

R Distributed I/O Controller The SRM1’s high-speed distributed I/O controller is a revolutionary design in PLC control. The SRM1 places all the processing power and control in the ultra compact master unit and allows you to distribute up to 256 ...

Page 2

... Note: 1. Information on EC Directives Individual OMRON products that comply with EC Directives conform to the common emission standards of EMC Directives. However, the emission characteristics of these products installed on customers’ equipment may vary depending on the configu- ration, wiring, layout, and other conditions of the control panel used. For this reason, customers are requested to check whether the emission characteristics of the entire machine or equipment comply with the EMC Directives ...

Page 3

... Terminal-block terminator Note: 1. Information on EC Directives Individual OMRON products that comply with EC Directives conform to the common emission standards of EMC Directives. However, the emission characteristics of these products installed on customers’ equipment may vary depending on the configu- ration, wiring, layout, and other conditions of the control panel used. For this reason, customers are requested to check whether the emission characteristics of the entire machine or equipment comply with the EMC Directives ...

Page 4

... CompoBus/S SRT2-Series terminals operation manual Programming manual SRM1/CPM1A/CPM2A/CPM2C programming manual 4 SRM1 Part number CPM1A-SRT21 CPM2C-SRT21 Part number CQM1-CIF02 CPM1-CIF01 CPM1-CIF11 Part number C200H-CN320-EU C200HS-CN220-EU Part number CQM1-PRO01–E C200H-PRO27-E C200H-CN222 C200H–CN422 Part number WS02-CXPC1-EJR-V2.0 WS02-CXPC1-EV2.0 Part number CPM1-EMU01-V1 CPM1-EEPROM-EMU01 Part number W318 W266 W353 ...

Page 5

SRM1 Nomenclature SRM1-C01-V2 CPU status indicators CompoBus/S communications status indicators Indicates the status of the CompoBus/S in operation and in communication with Slaves. Peripheral port communications status indicator Flashes when the peripheral port or RS-232C port is in communication. Terminal ...

Page 6

SRM1 J I/O ALLOCATION Maximum I/O points 256 points Input bits 160 bits: 00000 to 00915 (Bits not used as input bits can be used as work bits.) Output bits 160 bits: 01000 to 01915 (Bits not used as output ...

Page 7

SRM1 J COMPOBUS/S COMMUNICATIONS SPECIFICATIONS Communications method Coding method Connection method Communications High-speed mode baud rate Long-distance mode (See Note 2.) Communications High-speed mode cycle time Long-distance mode Maximum number of connectible terminals Communications High-speed mode distance Long-distance mode Cable ...

Page 8

SRM1 Dimensions Unit: mm (inch) J CPU/MASTER UNITS SRM1-C01-V2, SRM1-C02-V2 15 110 (4.33) 100 (3.94) 85.5 (3.37) The above dimensions apply to the SRM1-C02-V2. The SRM1-C01-V2 has no RS-232C port. J COMPOBUS/S SLAVE INPUT AND OUTPUT TERMINALS SRT1-ID04 (-1), SRT1-OD04 ...

Page 9

SRM1 RT1-ID16 (-1), SRT1-OD16 (-1) RT2-ID16 (-1), SRT2-OD16 (-1) 54 (2.12) SRT2-ID16T (-1) SRT2-MD16T (-1) SRT2-OD16T (-1) 105 (4.13) (50) 27 22–M3 84 180 (7.09) 170 Mounting Holes 170 ±0.2 (6.69 ±0.008) SRM1 50 20 (1.89) 28 Mounting ...

Page 10

SRM1 Unit: mm (inch) SRT1-ROC08, SRT1-ROF08 SRT2-ROC08, SRT2-ROF08 (2.12) SRT1-ROC16, SRT1-ROF16 SRT2-ROC16, SRT2-ROF16 155 (6.10 (2.12) 10 100 (3.94 ±0.2 ±.008) 21.5 11.5 Sixteen (1.97 ...

Page 11

SRM1 SRT2-VID08S SRT2-VID08S-1 SRT2-VOD08S SRT2-VOD08S-1 90 (3.54) 5 SRT2-VID16ML SRT2-VID16ML-1 SRT2-VOD16ML SRT2-VOD16ML-1 Mounting Brackets SRT2-ATT01 35 (1.38) 105.5 (4.15) SRT2-ATT02 35 (1.38) 32.5(1.28) 7.3 32 (1.26) 85 (3.35) 90 (3.54) 32 (1.26 (1.97) 35 (1.38) 55 (2.17) 70 ...

Page 12

SRM1 Unit: mm (inch) RT1-ID08S 50 (1.97) 4 SRT1-ND08S 12 100 (3.94) 92 Four (2.76) max. 50 (1.97) Cover opening and closing directions Four (2.95) 2.8 Cover opening and closing directions ...

Page 13

SRM1 SRT1-OD08S 50 (1.97) 4 SRT1-TID04 100 (3.94 Four 30.5 13 Two, 4.5 dia 61.8 (2.43) 41 (1.61) SRM1 75 (2.95) 2.8 Cover opening and closing directions 37 (1.46) Mounting Holes 40±0.2 ...

Page 14

SRM1 Unit: mm (inch) SRT1-XID04S SRT1-TKD04S 14 Two, 4.5 dia. 17 4.5 41.2 (1.62) 41 (1.61) Two, 4.5 dia (2.05 (1.61) SRM1 Mounting Holes Two, 4.2 dia ...

Page 15

SRM1 SRT1-XKD04S E3X-NM16 7 Two, 4.5 dia. 17 4.5 33 (1.30) 41 (1.61) Output indicator 7 8.3 7 32.2 (1.27) Eight, 2.4 dia (1.30) 10.7 7 8.3 SRM1 Mounting Holes Two, 4.2 dia ...

Page 16

SRM1 Unit: mm (inch) E3X-NTj6 E2C-T16 10 (0.39) 4 (0.16) 2 (0.08) R2 21.8 (0.86) E39-JID01 16 Output indicator 10 (0.39) Two, 2.4 dia. 8 10.7 13 OUT indicator STB indicator 0.5 (0.02) 22.6 2 (0.89) (0.08) 70 (2.76) 32.5 ...

Page 17

SRM1 SRT1-ID16P SRT1-OD16P 16 (0.63) 3.5 35 (1.38) SRT2-AD04 50 (1.97) SRT2-DA02 50 (1.97) 1.6 1.6 dia. 2.54 0.63 2. 38.1 60 (2.36) 105 (4.13 Mounting Holes Two, 4.2 dia ±0.2 ...

Page 18

SRM1 Unit: mm (inch) J CONNECTORS, CABLE, TERMINATORS SCN1-TH4 Branch Connector SCN1-TH4E Extension Connector SCN1-TH4T Connector Terminator SRS1-T Terminal–block Terminator (0.59) 17 (0.69) 20 (0.79) 10 (0.59) 17 (0.69) 20 (0.79) 10.1 Mounting Holes 30±0.2 ...

Page 19

... SRM1 1:N NT Link Connect the SRM1 to several NT–Series Programmable Terminals via the peripheral port using the CPM1-CIF11 serial communication adapter, as shown in the illustration at below. OMRON PTs that support the 1:N NT Link must be used. Programmable Terminals SRM1 RS-422 Host Link ...

Page 20

SRM1 Peripheral Port Connection Programmable Terminal IBM PC/AT or compatible computer 1:N Host Link Connection IBM PC/AT or compatible computer with RS-422 CPM1-CIF11 Serial Communications Adapter 20 C200H-CN320-EU cable (3 m) RS-232C Commu- nications Adapter CPM1-CIF01 C200HS-CN220-EU cable (2 m) ...

Page 21

... CS1 not possible for words LR16 to LR63 to be linked one-to-one with an SRM1. J PROGRAM TRANSFER UNIT Use Omron’s EEPROM program transfer unit to update programs in machines or program multiple controllers with the same program. The CPM1-EMU01-V1 Expansion Memory Unit connects to the peripheral port of micro and small PLCs. ...

Page 22

SRM1 Instruction Set J SEQUENCE INSTRUCTIONS Sequence Input Instructions Instruction LOAD LOAD NOT AND AND NOT OR OR NOT AND LOAD OR LOAD Sequence Output Instructions Instruction OUTPUT OUT NOT SET RESET KEEP DIFFERENTIATE UP DIFFERENTIATE DOWN Sequence Control Instructions ...

Page 23

SRM1 J LOGIC INSTRUCTIONS Instruction COMPLEMENT LOGICAL AND LOGICAL OR EXCLUSIVE OR EXCLUSIVE NOR J SHIFT INSTRUCTIONS Instruction SHIFT REGISTER WORD SHIFT ASYNCHRONOUS SHIFT REGISTER ARITHMETIC SHIFT LEFT ARITHMETIC SHIFT RIGHT ROTATE LEFT ROTATE RIGHT ONE DIGIT SHIFT LEFT ONE ...

Page 24

SRM1 J INSTRUCTION SET SUMMARY The following table lists the SRM1(-V2) instructions that have fixed function codes. Each instruction is listed by mnemonic and by instruction name. Use the numbers in the leftmost column as the left digit and the ...

Page 25

... SRM1 NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC MSPLC1 03/01 Specifications subject to change without notice. SRM1 OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U ...

Related keywords