PIC18F14K22-E/ML Microchip Technology, PIC18F14K22-E/ML Datasheet - Page 114

16KB Flash, 512bytes RAM, 256bytes EEPROM, 16MIPS, 1.8-5.5V Operation 20 QFN 4x4

PIC18F14K22-E/ML

Manufacturer Part Number
PIC18F14K22-E/ML
Description
16KB Flash, 512bytes RAM, 256bytes EEPROM, 16MIPS, 1.8-5.5V Operation 20 QFN 4x4
Manufacturer
Microchip Technology
Series
PIC® XLP™ 18Fr
Datasheets

Specifications of PIC18F14K22-E/ML

Core Processor
PIC
Core Size
8-Bit
Speed
48MHz
Connectivity
I²C, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
17
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Eeprom Size
256 x 8
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
20-VQFN Exposed Pad, 20-HVQFN, 20-SQFN, 20-DHVQFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F14K22-E/ML
Manufacturer:
MICROCHIP
Quantity:
1 000
PIC18F1XK22/LF1XK22
In addition to the expanded range of modes available
through the CCP1CON register and ECCP1AS
register, the ECCP module has two additional registers
associated with Enhanced PWM operation and
auto-shutdown features. They are:
• PWM1CON (Dead-band delay)
• PSTRCON (output steering)
13.1
The enhanced CCP module may have up to four PWM
outputs, depending on the selected operating mode.
These outputs, designated P1A through P1D, are
multiplexed with I/O pins on PORTC. The outputs that
are active depend on the CCP operating mode
selected. The pin assignments are summarized in
Table 13-2.
To configure the I/O pins as PWM outputs, the proper
PWM mode must be selected by setting the P1M<1:0>
and CCP1M<3:0> bits. The appropriate TRISC
direction bits for the port pins must also be set as
outputs.
13.1.1
The CCP modules utilize Timers 1, 2 or 3, depending
on the mode selected. Timer1 and Timer3 are available
to modules in Capture or Compare modes, while
Timer2 is available for modules in PWM mode.
TABLE 13-1:
The assignment of a particular timer to a module is
determined by the Timer-to-CCP enable bits in the
T3CON register (Register 12-1). The interactions
between
Figure 13-1. In Asynchronous Counter mode, the
capture operation will not work reliably.
DS41365D-page 114
CCP/ECCP Mode
Compare
Capture
ECCP Outputs and Configuration
PWM
the two modules are
CCP MODULE AND TIMER
RESOURCES
CCP MODE – TIMER
RESOURCE
Timer1 or Timer3
Timer1 or Timer3
Timer Resource
Timer2
summarized in
Preliminary
 2010 Microchip Technology Inc.

Related parts for PIC18F14K22-E/ML