SLATAFL6GBJI STEC, SLATAFL6GBJI Datasheet - Page 38

no-image

SLATAFL6GBJI

Manufacturer Part Number
SLATAFL6GBJI
Description
Manufacturer
STEC
Type
ATA Cardr
Datasheet

Specifications of SLATAFL6GBJI

Density
6GByte
Operating Supply Voltage (typ)
3.3/5V
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Package Type
Not Required
Mounting
Socket
Pin Count
68
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
3.18/4.75V
Operating Supply Voltage (max)
3.465/5.25V
Programmable
Yes
Lead Free Status / Rohs Status
Not Compliant
SimpleTech P/N:
(where xxx=capacity; U=RoHS compliant lead-free; I=Ind. Op. Temp;
F=fixed device; S=small data packet optimized)
Request Sense
(code: 03h)
This command requests an extended error code after a
command ends with an error. Refer to table below.
Code
00H
01H
09H
20H
21H
2FH
35H, 36H
11H
18H
05H, 30H-34H, 37H, 3EH
10H, 14H
3AH
1FH
0CH, 38H, 3BH, 3CH, 3FH
03H
22H
Seek
(code: 7Xh)
This command is effectively a NOP command to the Card
although it does perform a range check.
Set Features
(code: EFh)
This command is used by the host to establish or select
certain features.
Feature
CCH
BBH
01H
55H
66H
81H
SLATAFLxxxJ(U)(I)-(F)(S)
Enable 8-bit data transfers
Disable Read Look Ahead
Disable Power on Reset (POR)
establishment of defaults at Soft Reset
Disable 8-bit data transfers
4bytes of data apply on Read/Write
Long commands
Enable Power on Reset (POR)
establishment of default at Soft Reset
Description
No error detected
Self test OK (No error)
Miscellaneous Error - N/A
Invalid Command
Invalid Address (requested
Head or Sector invalid)
Address Overflow (address too
large)
Supply or generate Voltage Out
of Tolerance
Uncorrectable ECC Error
Correctable ECC Error - N/A
Self Test Diagnostic Failed
ID Not Found - N/A
Spare Sectors Exhausted
Data Transfer Error / Aborted
Command
Corrupted Media Format - N/A
Write / Erase Failed - N/A
Power Level 1 Disabled
Description
Document Part Number 61000-02810-110 July 2005
Set Multiple Mode
(code: C6h)
This command enables the card to perform Read and Write
Multiple operations and establishes the block count for these
commands.
Set Sleep Mode
(code: E6h or 99h)
This is the only command that allows the host to set the
card into Sleep mode. When the card is set to sleep mode,
the card clears the BSY line and issues an interrupt. The
card enters sleep mode and the only method to make the
card active again (back to normal operation) is by
performing a hardware reset or a software reset.
Stand By
(code: E2h or 96h)
This command is sets the card in Standby mode. If the
Sector Count Register is a value other than 0H, an Auto
Power Down is enabled and when the card returns to the idle
mode, the timer starts a countdown. The time is set in the
Sector Count Register.
Stand By Immediate
(code: E0h or 94h)
This command causes the card to set BSY, enter the
Standby mode, clear BSY and return the interrupt
immediately.
Translate Sector
(code: 87h)
This command allows the host a method of determining the
exact number of times a user sector has been erased and
programmed. This command is not supported.
Wear Level
(code: F5h)
This command is effectively a NOP command and only
implemented for backward compatibility. The Sector Count
Register will always be returned with an 00h indicating Wear
Level is not needed.
Write Buffer
(code: E8h)
This command enables the host to overwrite the contents of
the card’s sector buffer with any data pattern desired.
Write Long Sector
(code: 32h or 33h)
This command is provided for compatibility purposes and is
similar to the Write Sector(s) command except that it writes
516 bytes instead of 512 bytes.
PC CARD
Page 38

Related parts for SLATAFL6GBJI