ADE7569ASTZF16 Analog Devices Inc, ADE7569ASTZF16 Datasheet - Page 36

IC ENERGY METER MCU 16K 64LQFP

ADE7569ASTZF16

Manufacturer Part Number
ADE7569ASTZF16
Description
IC ENERGY METER MCU 16K 64LQFP
Manufacturer
Analog Devices Inc
Datasheets

Specifications of ADE7569ASTZF16

Applications
Energy Measurement
Core Processor
8052
Program Memory Type
FLASH (16 kB)
Controller Series
ADE75xx
Ram Size
512 x 8
Interface
I²C, SPI, UART
Number Of I /o
20
Voltage - Supply
3.135 V ~ 3.465 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
64-LQFP
Ic Function
Single Phase Energy Measurement IC
Supply Voltage Range
3.13V To 3.46V, 2.4V To 3.7V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
LQFP
No. Of Pins
64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7569ASTZF16
Manufacturer:
AD
Quantity:
310
Part Number:
ADE7569ASTZF16
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
ADE7569ASTZF16-RL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
ADE7116/ADE7156/ADE7166/ADE7169/ADE7566/ADE7569
Table 27. Power Supply Event Timing Operating Modes
Parameter
t
t
t
t
1
2
3
4
SAG LEVEL TRIP POINT
SAGCYC = 1
Time
10 ns min
10 ns min
30 ms typ
130 ms typ
Figure 36. Power Supply Management Interrupts and Battery Switchover with V
V
P
2.75V
V
1.2V
– V
DCIN
V
BATTERY SWITCH
BATTERY SWITCH
DD
N
ENABLED ON
ENABLED ON
LOW V
LOW V
Description
Time between when V
Time between when V
Time between when V
battery switchover.
Time between when power supply restore conditions are met (V
0b01 or V
SAG LEVEL
TRIP POINT
DCIN
DD
V
P
V
1.2V
V
2.75V
− V
DCIN
V
V
V
BAT
SW
SW
DD
DD
N
> 2.75 V if BATPRG[1:0] = 0b00) and when V
Figure 37. Power Supply Management Transitions Between Modes
DCIN
DD
DCIN
falls below 2.75 V and when battery switchover occurs.
goes below 1.2 V and when FVDCIN is raised.
falls below 1.2 V and when battery switchover occurs if V
PSM0
PSM0
SAG EVENT
(FSAG = 1)
SAG EVENT
Rev. B | Page 36 of 152
30ms MIN.
V
DCIN
EVENT
V
(FVDCIN = 1)
DCIN
PSM1 OR PSM2
PSM1 OR PSM2
EVENT
SWOUT
t
DD
1
or V
130ms MIN.
t
switches to V
V
3
DCIN
DCIN
DCIN
Enabled for Battery Switchover
EVENT
IF SWITCHOVER ON LOW V
ENABLED, AUTOMATIC BATTERY
> 1.2 V and V
SWITCHOVER OCCURS. V
IS CONNECTED TO V
DD
PSM0
PSM0
.
BSO EVENT
(FBSO = 1)
DD
DCIN
> 2.75 V if BATPRG[1:0] =
is enabled to cause
BAT
SWOUT
DCIN
.
IS

Related parts for ADE7569ASTZF16