TLE6240GPNT Infineon Technologies, TLE6240GPNT Datasheet - Page 28

TLE6240GPNT

Manufacturer Part Number
TLE6240GPNT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE6240GPNT

Switch Type
Low Side
Power Switch Family
TLE6240
Input Voltage
-0.3 to 7V
Power Switch On Resistance
1Ohm
Output Current
500mA
Number Of Outputs
16
Mounting
Surface Mount
Supply Current
5mA
Package Type
DSO
Operating Temperature (min)
-40C
Operating Temperature (max)
150C
Operating Temperature Classification
Automotive
Pin Count
36
Lead Free Status / Rohs Status
Compliant
The AND operation implies that the output can be switched off by the SPI data bit input, even if the corresponding
parallel input is in the ON state.
SPI Priority for OFF-State
This also implies that the serial input data bit can only switch the output channel ON if the corresponding parallel
input is in the ON state.
If the AND operation is programmed it is latched until it is overwritten by the OR operation.
6.1.5.6
LLHH LLLL HLLH LLLH: OR operation between parallel inputs and data bits, i.e channel 1, 5 and 8 will be switched
on.
The next command is now: LHHH LLLL HHHH LLLL
LHHH LLLL as command word has no special meaning and will not be accepted. The output states will not be
changed and the shift register will be reset (at the next CS SO Data all ‘0’).
6.2
For full diagnosis there are two diagnostic bits per channel configured as shown in
Figure 21
A definite distinction between open load and short to ground is specified by design.
The standard way of obtaining diagnostic information is as follows:
Clock in serial information into SI pin and wait approximately 150 µs to allow the outputs to settle. Clock in the
identical serial information once again - during this process the data coming out at SO contains the bit
combinations representing the diagnosis conditions as described in
Reset of the Diagnosis Register
The diagnosis register is reset after reading the diagnosis data (after the falling CS edge). This is done for
channels 1-8 and channels 9-16 separately depending on the previous command.
Data Sheet
Normal function: The bit combination HH indicates that there is no fault condition, i.e. normal function.
Overload, Short Circuit to Battery (SCB) or Overtemperature: HL is set when the current limitation gets
active, i.e. there is a overload, short to supply or overtemperature condition.
Open load: An open load condition is detected when the drain voltage decreases below 3 V (typ.). LH bit
combination is set.
Short Circuit to GND: If a drain to ground short circuit exists and the drain to ground current exceeds 100 µA,
short to ground is detected and the LL bit combination is set.
Example for an access to channel 1 to 8
Diagnostics
Two Bits per Channel Diagnostic Feedback
Diagnostic Serial Data OUT SO
HH
HL
LH
LL
15
Ch.8
Ch.16 Ch.15
14
Normal function
Overload, Shorted Load or Overtemperature
Open Load
Shorted to Ground
13
Ch.7
12
11 10
Ch.6
Ch.14
9
Ch.13
Ch.5
28
8
7
6- - - - -
Smart 16-Channel Low-Side Switch
Figure
21.
Figure
Control of the Device
21.
Rev.3.3, 2010-02-15
TLE6240GP

Related parts for TLE6240GPNT