DS2151QNB Maxim Integrated Products, DS2151QNB Datasheet - Page 15

IC TXRX T1 1-CH 5V LP IND 44PLCC

DS2151QNB

Manufacturer Part Number
DS2151QNB
Description
IC TXRX T1 1-CH 5V LP IND 44PLCC
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS2151QNB

Function
Single-Chip Transceiver
Interface
T1
Number Of Circuits
1
Voltage - Supply
4.75 V ~ 5.25 V
Current - Supply
65mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
44-LCC, 44-PLCC
Includes
Alarm Detector and Generator, CSU Loop Codes Generator and Detector, DSX-1 and CSU Line Build-Outs Generator
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power (watts)
-
4.1 Local Loopback
When CCR1.6 is set to a 1, the DS2151Q will be forced into Local Loopback (LLB). In this loopback,
data will continue to be transmitted as normal through the transmit side of the SCT. Data being received
at RTIP and RRING will be replaced with the data being transmitted. Data in this loopback will pass
through the jitter attenuator and the jitter attenuator should be programmed to be in the transmit path.
LLB is primarily used in debug and test applications. See
4.2 Remote Loopback
When CCR1.4 is set to a 1, the DS2151Q will be forced into Remote Loopback (RLB). In this loopback,
data recovered off the T1 line from the RTIP and RRING pins will be transmitted back onto the T1 line
(with any BPVs that might have occurred intact) via the TTIP and TRING pins. Data will continue to
pass through the receive side of the DS2151Q as it would normally and the data at the TSER input will be
ignored. Data in this loopback will pass through the jitter attenuator. RLB is used to place the DS2151Q
into “line” loopback, which is a requirement of both ANSI T1.403 and AT&T TR62411. See
for more details.
4.3 Payload Loopback
When CCR1.1 is set to a 1, the DS2151Q will be forced into Payload Loopback (PLB). Normally, this
loopback is only enabled when ESF framing is being performed. In a PLB situation, the DS2151Q will
loop the 192 bits of payload data (with BPVs corrected) from the receive section back to the transmit
section. The FPS framing pattern, CRC6 calculation, and the FDL bits are not looped back, they are
reinserted by the DS2151Q. When PLB is enabled, the following will occur:
4.4 Framer Loopback
When CCR1.0 is set to a 1, the DS2151Q will enter a Framer Loopback (FLB) mode. This loopback is
useful in testing and debugging applications. In FLB, the DS2151Q will loop data from the transmit side
back to the receive side. When FLB is enabled, the following will occur:
1) Data will be transmitted from the TTIP and TRING pins synchronous with RCLK instead of
2) All the receive side signals will continue to operate normally.
3) The TCHCLK and TCHBLK signals are forced low.
4) Data at the TSER pin is ignored.
5) The TLCLK signal will become synchronous with RCLK instead of TCLK.
1) Unless the RLB is active, an unframed all 1s code will be transmitted at TTIP and TRING.
2) Data off the T1 line at RTIP and RRING will be ignored.
3) The RCLK output will be replaced with the TCLK input.
TCLK.