h7cx-a11d1 Omron Corporation, h7cx-a11d1 Datasheet - Page 27

no-image

h7cx-a11d1

Manufacturer Part Number
h7cx-a11d1
Description
Multifunction Preset Counter
Manufacturer
Omron Corporation
Datasheet
Total and Preset Counter Operation
The H7CX has a total counter, separate from the 1-stage preset counter, for counting the total accumulated value.
Batch Counter Operation
The H7CX has a batch counter, separate from the 1-stage preset counter, for counting the number of times the count has been completed.
Note: 1. The batch count value is held at 0 during batch counter reset input.
Total reset/reset 2
Total count value
Batch count set value
(Sub-display)
OUT1 (batch output)
Batch count value
(Main display)
Present value
Reset/reset 1
Reset 2 (batch
counter reset)
2. If the batch count set value is 0, batch count will be performed but there will be no batch output.
3. The batch count value returns to 0 when it reaches 999,999 (9,999 for 4-digit models).
4. Once batch input has been turned ON, it will return to the ON state after power interruptions.
5. If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output will turn ON.
6. After batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the batch count
Present value
value.
999999
Set value
Note: The full scale (FS) for H7CX 4-digit models is 9999.
Reset 1
OUT2
0
0
0
0
Note: The above is for when the output mode is C.
1
2
• The total counter continues to count the
• The total count value is reset when the
• The counting range of the total counter is
• The batch counter continues after count
• Batch output is held until batch counter
• When the batch counter reset input is
• If the reset key is pressed while the batch
• Although the count value can be incre-
total accumulated value when the present
value is reset using reset/reset 1 input
(reset key).
total reset/reset 2 input is turned ON. If the
reset key is pressed while the total count
value is displayed, the total count value is
reset. The present value is also reset at
this time.
−99,999 to 999,999 (−999 to 9,999). The
total count value returns to 0 when it
reaches the full scale limit.
completion.
reset is input.
turned ON, the batch count value is reset,
and batch output turns OFF.
count value is displayed, the batch count
value is reset and batch output turns OFF.
The present value is also reset at this time.
mented and decremented, the batch count
is only incremented.
H7CX-A
27

Related parts for h7cx-a11d1