h7cx-a11d1 Omron Corporation, h7cx-a11d1 Datasheet - Page 56

no-image

h7cx-a11d1

Manufacturer Part Number
h7cx-a11d1
Description
Multifunction Preset Counter
Manufacturer
Omron Corporation
Datasheet
■ Output Mode Settings
■ Hold Function
The measurement value (display value) and output are sustained while the hold input is ON.
Note: The output will maintain the current status when the hold key is pressed.
Example
Output
setting
mode
Output mode
Lower limit
setting
(LO)
(HI-LO)
(AREA)
Lower
Upper
Upper
lower
Area
limit
limit
limit
(LO)
and
(HI)
Condition
condition
ON
ON condition: measurement value ≤ comparison value 1 or measurement value ≥ comparison value 2
Note: When comparison value 1 ≥ comparison value 2, the output is always ON regardless of the
Comparison value 1 ≤ measurement value ≤
Comparison value 2
comparison value.
Comparison value 1 ≤ Comparison value 2
Comparison value
(Lower-limit)
Hold input
(Hold Key)
Comparison value 1
(Lower-limit)
ON condition: Measurement value ≥ Comparison value
Comparison value 2
(Upper-limit)
Measurement value
Display value
ON condition: Measurement value ≤ Comparison value
Measurement value
Measurement value
Comparison value
(Upper-limit)
OUT
Comparison value
(Lower-limit)
Comparison value 1
Measurement value
Comparison value 2
OUT
OUT
OUT
OUT
Operation
Actual input
Comparison value 2 ≤ measurement value ≤
Comparison value 1
Comparison value 1 > Comparison value 2
Sustained output
Sustained display value