Key Protect Level (kypt)
Set the key protect level.
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the
key protect level (KP-1 to KP-5). The key protect level is set in the function setting mode. The key protect indicator is lit while the key-protect
switch is set to ON. Confirm the ON/OFF status of the key-protect switch after the H7CX is mounted to the panel.
Note: Changing mode to DIP switch monitor mode or function setting mode.
KP-1 (default setting)
KP-2
KP-3
KP-4
KP-5
Note: Factory-set to OFF
Level
(See note)
Key protect indicator
OFF
ON
Meaning
No
No
No
No
No
Changing mode
(See note.)
Yes
Yes
Yes
Yes
No
Switching display
during operation
Details
Yes
No
Yes
No
No
Hold key
Yes
Yes
No
No
No