CDB5532U Cirrus Logic Inc, CDB5532U Datasheet - Page 9

BOARD EVAL FOR CS5532U ADC

CDB5532U

Manufacturer Part Number
CDB5532U
Description
BOARD EVAL FOR CS5532U ADC
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CDB5532U

Number Of Adc's
2
Number Of Bits
24
Sampling Rate (per Second)
3.84k
Data Interface
Serial
Inputs Per Adc
1 Differential
Input Range
±2.5 V
Power (typ) @ Conditions
35mW @ 3.84kSPS
Voltage Supply Source
Analog and Digital, Dual ±
Operating Temperature
-40°C ~ 85°C
Utilized Ic / Part
CS5532
Description/function
Audio DSPs
Operating Supply Voltage
5 V
Product
Audio Modules
For Use With/related Products
C8051F320
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1159
Calibration Window: The Calibration window (Figure 4) permits the user to access the calibration regis-
ters for each channel of the CS5532 and also perform self and system offset or gain calibrations on either
of the channels. Prior to performing calibrations however, the channel setup registers should be modified
to configure the part for the desired operating mode (see the section ‘Setup Window” on page 7 for more
details). Note that offset calibration should be performed before gain calibration to ensure accurate re-
sults. Refer to the CS5532 datasheet for more details.
Self Offset or Gain Calibrations:
System Offset Calibrations:
System Gain Calibrations:
DS807DB1
1) Pull down the Self Offset or Self Gain box, and select the setup number you want to use to cali-
2) The offset and gain register values will automatically update when the calibration is completed.
1) Attach a grounded input to the physical channel you want to calibrate. Note that the grounded input
2) Pull down the System Offset box, and select the setup number you want to use to calibrate the
3) When the calibration is complete, the screen will automatically update the offset and gain registers
1) Attach a full-scale input to the physical channel you want to calibrate.
2) Pull down the System Gain box, and select the setup number you want to use to calibrate the
3) When the calibration is complete, the screen will automatically update the offset and gain registers
brate the channel.
must be within the common mode range of the particular amplifier (1x-64x) for proper operation.
channel.
with the new values.
channel.
with the new values.
Figure 4. CDB5532U Calibration Window
CDB5532U
9