ECJ-2F60J226M Panasonic - ECG, ECJ-2F60J226M Datasheet - Page 8

CAP CERAMIC 22UF 6.3V 0805 X6S

ECJ-2F60J226M

Manufacturer Part Number
ECJ-2F60J226M
Description
CAP CERAMIC 22UF 6.3V 0805 X6S
Manufacturer
Panasonic - ECG
Series
ECJr

Specifications of ECJ-2F60J226M

Capacitance
22µF
Voltage - Rated
6.3V
Tolerance
±20%
Temperature Coefficient
X6S
Mounting Type
Surface Mount, MLCC
Operating Temperature
-55°C ~ 105°C
Features
Low ESR
Applications
General Purpose
Package / Case
0805 (2012 Metric)
Size / Dimension
0.079" L x 0.049" W (2.00mm x 1.25mm)
Thickness
1.25mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Ratings
-
Lead Spacing
-
Other names
ECJ2F60J226M
PCC2477TR
CLASSIFICATION
SUBJECT
When uncertainty occurs in the weather resistance characteristic tests (temperature cycle, moisture resistance,
moisture resistant loading, high temperature resistant loading), the same tests shall be performed for the capacitor itself.
For High Cap Type, signal voltage may be unable to be applied to depending on conditions of measuring instruments.
We would appreciate it if you would confirm whether High Cap Type is under the measurable environment or not by
checking that the fixed signal voltage is applied or not. (For example, ALC function is ON, HPA is expanded.)
Note ;
Measuring Instrument
Measuring Mode
Recommended
No
16
High
perature Re-
sistant
Loading
High Capacitance (P/N : ECJ2F60J226M) Common Specification
Measuring Jig
Contents
Tem-
Multilayer Ceramic Chip Capacitors (EIA 0805)
Appear-
ance
Capaci-
tance
tan δ
I.R.
4284A Precision LCR Meter (Agilent Technologies)
Parallel Mode
16034E Test Fixture (Agilent Technologies)
There shall be no cracks and other
mechanical damage.
0.25 max.
10/C MΩ min.
(C : Nominal Cap. in µF)
Temp.
Char.
X6S
SPECIFICATION
Change from the value be-
fore test.
Within +/- 20 %
Our Standard Measuring Instrument
Performance
Table 2
Table 3
For the class2 capacitors, perform the volt-
age
treatment in par. 5-1-2.
Solder the specimen to the testing jig shown
in Fig. 2.
Before the measurement after test, the spe-
cimen shall be left to stand at room tempera-
ture for the following period : 48+/-4 h
Test temperature :
Applied voltage : Rated voltage
Charge/discharge current : within 50 mA.
Test period : 1000+48/0 h
Max. Rated temp. +/-3°C
Test Method
(DC Voltage)
No.
PAGE
DATE
151S-ECJ-KGS39E
Aug 28, 2008
6 of 7