BCCM6033SQ Cooper/Bussmann, BCCM6033SQ Datasheet - Page 180

no-image

BCCM6033SQ

Manufacturer Part Number
BCCM6033SQ
Description
FUSEBLOCK CLASS CC 13/32X1-1/2"
Manufacturer
Cooper/Bussmann
Series
BCCMr
Type
Blockr
Datasheet

Specifications of BCCM6033SQ

Fuse Size
Class CC
Number Of Circuits
3
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Current Rating
20A
Product
Block
Fuse Size / Group
Class CC
Voltage Rating
600 Volts
Mounting Style
Screw
Body Material
Thermoplastic
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Data Sheet: 5022
176
TPM & TPMDS
TPMDS - Telpower
TPM - Telpower
Ampere Ratings: 3-30A
Voltage Rating: 80Vdc
Interrupting Rating: 20,000A
Agency Information:
UL Recognized (investigated to UL 1801) as a
disconnect switch for the interruption of load current
by means of withdrawing the fuse pullout.
Recognized to U.S. and Canadian requirements under the
component recognition program of Underwriters
Laboratories Inc.
Files E219046 and E56412.
Catalog Number
TPM-3
TPM-4
TPM-5
TPM-6
TPM-7
TPM-8
TPM-10
TPM-12
TPM-15
TPM-20
TPM-25
TPM-30
TPMDS-E
TPMDS-M
Telpower
Telpower
®
Description
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Disconnect, English
Miniature Disconnect, Metric
®
Miniature Fuse - Current Limiting
®
®
DC Power Protection Systems
Miniature Fused Disconnect Switch
Miniature Fused Disconnect Switch
Look for Telpower® BLUE™ fuses exclusively from Cooper Bussmann.
For complete specification data, call Bussmann Information Fax ~ 636.527.1450
Ampere Rating
3A
4A
5A
6A
7A
8A
10A
12A
15A
20A
25A
30A
3-30A
3-30A
General Information:
• Smallest and most versatile fused disconnect
• Small size allows for assembly into 1 U (1.75 inch /
• AmpColor ID™ System for easy fuse replacement.
• Switch design provides for easy panel mounting by single
• Local and remote open fuse indication. Local alarm
• Current-limiting capability
• Complete system coordination capability
• Load connection: 1/4 inch quick-connect or bolted
• Line connection: 1/4 inch quick-connect or screw
• Maximum alarm circuit current: 20 mA
• Materials:
switch available.
44.5 mm) panel.
captive 4-40 (M3) nut and panel notch integral to switch
footprint.
indication provided by LED on TPM fuse.
connection with 10-32 (M5) captive nut.
connection with clearance hole for #10 (M5) bolt.
Fuse housing - black thermoplastic, UL 94 V-0, 170ºC RTI
Switch housing - black thermoplastic, UL 94 V-0, 140ºC RTI
CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer
to Data Sheet: 8002 or contact Bussmann Application
Engineering for more information.
NOTES:
1. The resistance, R, must be provided by the end-user
2. The fuse is polarized to maintain proper orientation with
to limit the alarm output current to a maximum of
20 mA. The value, R, should be calculated using the
system voltage value.
the switch housing. The line and load terminals are
identified on the switch housing.
the END-USER CIRCUITRY must still be supplied
to provide a resistive path to the return for the
local alarm to properly function.
TPM Alarm Schematic
If remote alarm functionality is not required,
TPM & TPMDS
Bussmann
®