ATMEGA645P-MUR Atmel, ATMEGA645P-MUR Datasheet - Page 187

no-image

ATMEGA645P-MUR

Manufacturer Part Number
ATMEGA645P-MUR
Description
MCU AVR 64KB FLASH 16MHZ 64QFN
Manufacturer
Atmel
Series
AVR® ATmegar
Datasheets

Specifications of ATMEGA645P-MUR

Core Processor
AVR
Core Size
8-Bit
Speed
16MHz
Connectivity
SPI, UART/USART, USI
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
54
Program Memory Size
64KB (32K x 16)
Program Memory Type
FLASH
Eeprom Size
2K x 8
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-VFQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
8285B–AVR–03/11
ATmega165A/165PA/325A/325PA/3250A/3250PA/6
D
S
S
S
R
Table 19-2
that Normal Speed mode has higher toleration of baud rate variations.
Table 19-2.
Table 19-3.
The recommendations of the maximum receiver baud rate error was made under the assump-
tion that the Receiver and Transmitter equally divides the maximum total error.
There are two possible sources for the receivers baud rate error. The Receiver’s system clock
(XTAL) will always have some minor instability over the supply voltage range and the tempera-
ture range. When using a crystal to generate the system clock, this is rarely a problem, but for a
resonator the system clock may differ more than 2% depending of the resonators tolerance. The
second source for the error is more controllable. The baud rate generator can not always do an
F
M
slow
# (Data+Parity Bit)
# (Data+Parity Bit)
10
10
D
D
5
6
7
8
9
5
6
7
8
9
and
Sum of character size and parity size (D = 5 to 10 bit)
Samples per bit. S = 16 for Normal Speed mode and S = 8 for Double Speed
mode.
First sample number used for majority voting. S
for Double Speed mode.
Middle sample number used for majority voting. S
S
is the ratio of the slowest incoming data rate that can be accepted in relation to the
receiver baud rate. R
accepted in relation to the receiver baud rate.
Recommended Maximum Receiver Baud Rate Error for Normal Speed Mode
(U2Xn = 0)
Recommended Maximum Receiver Baud Rate Error for Double Speed Mode
(U2Xn = 1)
M
Table 19-3
= 5 for Double Speed mode.
R
R
slow
slow
93.20
94.12
94.81
95.36
95.81
96.17
94.12
94.92
95.52
96.00
96.39
96.70
list the maximum receiver baud rate error that can be tolerated. Note
(%)
(%)
fast
R
R
105.66
104.92
104,35
103.90
103.53
103.23
106.67
105.79
105.11
104.58
104.14
103.78
fast
fast
is the ratio of the fastest incoming data rate that can be
(%)
(%)
Max Total Error (%)
Max Total Error (%)
+5.66/-5.88
+4.92/-5.08
+4.35/-4.48
+3.90/-4.00
+3.53/-3.61
+3.23/-3.30
+5.79/-5.88
+5.11/-5.19
+4.58/-4.54
+4.14/-4.19
+3.78/-3.83
+6.67/-6.8
F
= 8 for normal speed and S
M
= 9 for normal speed and
Recommended Max
Recommended Max
Receiver Error (%)
Receiver Error (%)
± 2.5
± 2.0
± 1.5
± 1.5
± 1.5
± 1.0
± 3.0
± 2.5
± 2.0
± 2.0
± 1.5
± 1.5
F
187
= 4

Related parts for ATMEGA645P-MUR